Multi-parametric whole-body MRI evaluation discerns vital from non-vital multiple myeloma lesions as validated by 18F-FDG and 11C-methionine PET/CT. Issue 155 (October 2022)
- Record Type:
- Journal Article
- Title:
- Multi-parametric whole-body MRI evaluation discerns vital from non-vital multiple myeloma lesions as validated by 18F-FDG and 11C-methionine PET/CT. Issue 155 (October 2022)
- Main Title:
- Multi-parametric whole-body MRI evaluation discerns vital from non-vital multiple myeloma lesions as validated by 18F-FDG and 11C-methionine PET/CT
- Authors:
- Heidemeier, Anke
Schloetelburg, Wiebke
Thurner, Annette
Metz, Corona
Heidemeier, Heike
Rasche, Leo
Martin Kortuem, K.
Boeckle, David
Weiland, Elisabeth
Benkert, Thomas
Nickel, Dominik
Werner, Rudolf
Buck, Andreas Konrad
Bley, Thorsten Alexander - Abstract:
- Graphical abstract: Highlights: Multi-parametric whole-body MRI facilitates a reproducible, standardized whole-body MR analysis in multiple myeloma. A prototypical DIXON-type sequence allows for fat quantification on automatically generated fat fraction maps. Substantial concordance between MRI classification of lesions and PET assessment according to Deauville criteria. Abstract: Purpose: We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18 F-fluorodeoxyglucose ( 18 F-FDG) and 11 C-methionine ( 11 C-MET). Methods and Materials: This retrospective single-center study included 44 MM patients, who received both 18 F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18 F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11 C-MET PET was available. Results: Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18 F-FDG-PET or 11 C-MET-PET. MRI-rated non-vital lesions correlated with PET-basedGraphical abstract: Highlights: Multi-parametric whole-body MRI facilitates a reproducible, standardized whole-body MR analysis in multiple myeloma. A prototypical DIXON-type sequence allows for fat quantification on automatically generated fat fraction maps. Substantial concordance between MRI classification of lesions and PET assessment according to Deauville criteria. Abstract: Purpose: We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18 F-fluorodeoxyglucose ( 18 F-FDG) and 11 C-methionine ( 11 C-MET). Methods and Materials: This retrospective single-center study included 44 MM patients, who received both 18 F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18 F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11 C-MET PET was available. Results: Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18 F-FDG-PET or 11 C-MET-PET. MRI-rated non-vital lesions correlated with PET-based DS ≤ 3. When results of mpWB-MRI were compared to 18 F-FDG, a fair inter-observer agreement was recorded (ICC = 0.52, k = 0.53, p <.01), while for 11 C-MET, an excellent concordance rate was achieved (ICC = 0.81, k = 0.79, p <.01). Conclusion: The proposed mpWB-MRI interpretation algorithm allowed to assess tumor activity of myeloma lesions with high inter-observer reproducibility. We observed a substantial concordance between the mpWB-MRI classification of lesions and PET assessment based on a semi-automatically calculated 5-point scoring system analogous to the Deauville scores. … (more)
- Is Part Of:
- European journal of radiology. Issue 155(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 155(2022)
- Issue Display:
- Volume 155, Issue 155 (2022)
- Year:
- 2022
- Volume:
- 155
- Issue:
- 155
- Issue Sort Value:
- 2022-0155-0155-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- Multiple myeloma -- Diffusion-weighted MRI -- Whole-body MRI -- Multi-parametric MRI -- Chemical shift imaging -- Fat fraction -- 11C-methionine -- 18F-FDG -- PET -- Positron emission tomography
ADC apparent diffusion coefficient -- CSI chemical shift imaging -- DWI diffusion-weighted imaging -- DS Deauville score -- 18F-FDG 18F-2'-deoxy-2'-fluoro-d-glucose -- PET/CT positron emission tomography/computed tomography -- FF fat fraction -- 11C-MET 11C-methionine -- MM multiple myeloma -- mpWB-MRI multi-parametric whole-body magnetic resonance imaging -- MRD minimal residual disease -- SUV standardized uptake value -- TLG total lesion glycolysis
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110493 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23895.xml