Rhodotron and rotating target: A solution towards micro-spot for high energy and high dose rate bremsstrahlung sources. (November 2022)
- Record Type:
- Journal Article
- Title:
- Rhodotron and rotating target: A solution towards micro-spot for high energy and high dose rate bremsstrahlung sources. (November 2022)
- Main Title:
- Rhodotron and rotating target: A solution towards micro-spot for high energy and high dose rate bremsstrahlung sources
- Authors:
- He, Xiaozhong
Yang, Liu
Liao, Shuqing
Tang, Ruo
Peng, Yufei
Wang, Yi
Yang, Guojun
Wei, Tao
Yang, Xinglin
Jiang, Xiaoguo
Long, Jidong
Zhang, Huang
Xie, Weiping - Abstract:
- Abstract: High energy over MeV bremsstrahlung sources that employ normal conducting radio frequency linear accelerators have expanding applications in industrial computerized tomography (CT) for non-destructive inspection and evaluation. The X-ray spot size that mainly affects the imaging quality is yet limited by the electron beam width in the high resolution CT systems. In a short exposure time, high beam power is required to generate sufficient photons to improve the signal to noise ratio of imaging. However, with ∼kW level of average beam power these linear accelerators usually have a beam spot size over 1 mm since the temperature rising due to the beam energy deposition in the target should be far below its melting point. We propose a concept of using a Rhodotron-based accelerator to provide high power electron beams in a long duration pulse and a rotating target to mitigate the overheating issue, such that the gap between micro-spot and high dose rate can be bridged in the high energy bremsstrahlung sources. This article presents an in-depth simulation work to discuss and evaluate this scheme of X-ray source. The simulations of beam dynamics in the accelerator and bremsstrahlung process in the target predict the generated X-rays with a spot size as small as 68 μm at full-width half-maximum and a dose rate as high as 4700 cGy/min from a 9 MeV electron beam interacting with a 1 mm thickness tantalum target. Further thermal analysis in the rotating target indicates aAbstract: High energy over MeV bremsstrahlung sources that employ normal conducting radio frequency linear accelerators have expanding applications in industrial computerized tomography (CT) for non-destructive inspection and evaluation. The X-ray spot size that mainly affects the imaging quality is yet limited by the electron beam width in the high resolution CT systems. In a short exposure time, high beam power is required to generate sufficient photons to improve the signal to noise ratio of imaging. However, with ∼kW level of average beam power these linear accelerators usually have a beam spot size over 1 mm since the temperature rising due to the beam energy deposition in the target should be far below its melting point. We propose a concept of using a Rhodotron-based accelerator to provide high power electron beams in a long duration pulse and a rotating target to mitigate the overheating issue, such that the gap between micro-spot and high dose rate can be bridged in the high energy bremsstrahlung sources. This article presents an in-depth simulation work to discuss and evaluate this scheme of X-ray source. The simulations of beam dynamics in the accelerator and bremsstrahlung process in the target predict the generated X-rays with a spot size as small as 68 μm at full-width half-maximum and a dose rate as high as 4700 cGy/min from a 9 MeV electron beam interacting with a 1 mm thickness tantalum target. Further thermal analysis in the rotating target indicates a significant improvement of beam power handling in comparison with the conventional stationary one. Highlights: Using a 9 MeV Rhodotron is proposed to bridge the gap between micro-spot and high dose rate in the high energy bremsstrahlung sources. This scheme allows using a rotating target to migrate the overheating issue in the target. In-depth simulations suggest X-ray spot size 68 μm at FWHM and dose rate 4700 cGy/min with 1 kW power of incident electron beams. Thermal analysis indicates significant improvement of beam power handling in the target. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 189(2022)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 189(2022)
- Issue Display:
- Volume 189, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 189
- Issue:
- 2022
- Issue Sort Value:
- 2022-0189-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2022.110446 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23889.xml