Evaluation of point‐of‐care analysers for blood gas and clinical chemistry in Hermann's tortoises (Testudo hermanni). (1st August 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of point‐of‐care analysers for blood gas and clinical chemistry in Hermann's tortoises (Testudo hermanni). (1st August 2018)
- Main Title:
- Evaluation of point‐of‐care analysers for blood gas and clinical chemistry in Hermann's tortoises (Testudo hermanni)
- Authors:
- Di Girolamo, N.
Ferlizza, E.
Selleri, P.
Nardini, G.
Isani, G. - Abstract:
- Abstract : Objective: To assess the agreement between point‐of‐care and laboratory analysers in measuring biochemical and blood gas analytes in venous samples from tortoises and to define preliminary reference intervals for venous blood gas analysis in Hermann's tortoises ( Testudo hermanni ). Materials and Methods: Jugular venous blood samples from 47 Hermann's tortoises underwent paired analysis with a portable gas analyser (i‐STAT 1, Abaxis), a portable chemical analyser (VetScan VS2, Abaxis), and with the respective reference analysers. Agarose gel electrophoresis was used to determine albumin concentrations on 12 specimens. Agreement was evaluated with Bland–Altman plots and regression analysis using the Passing–Bablok method. Results: Point‐of‐care analysers had variable agreement with the reference analysers, presenting constant or proportional bias depending on the analyte. Relevant analytes in reptiles, such as ionised and total calcium, had acceptable agreement. The method for determining albumin concentration currently available in both point‐of‐care and laboratory analysers significantly overestimated albumin concentrations as compared to protein electrophoresis. Clinical Significance: While the use of POC analysers is extremely advantageous in small animal primary care facilities, agreement between point‐of‐care and laboratory analysers varies depending on the analyte. For certain analytes, interchangeability of results is limited and specific referenceAbstract : Objective: To assess the agreement between point‐of‐care and laboratory analysers in measuring biochemical and blood gas analytes in venous samples from tortoises and to define preliminary reference intervals for venous blood gas analysis in Hermann's tortoises ( Testudo hermanni ). Materials and Methods: Jugular venous blood samples from 47 Hermann's tortoises underwent paired analysis with a portable gas analyser (i‐STAT 1, Abaxis), a portable chemical analyser (VetScan VS2, Abaxis), and with the respective reference analysers. Agarose gel electrophoresis was used to determine albumin concentrations on 12 specimens. Agreement was evaluated with Bland–Altman plots and regression analysis using the Passing–Bablok method. Results: Point‐of‐care analysers had variable agreement with the reference analysers, presenting constant or proportional bias depending on the analyte. Relevant analytes in reptiles, such as ionised and total calcium, had acceptable agreement. The method for determining albumin concentration currently available in both point‐of‐care and laboratory analysers significantly overestimated albumin concentrations as compared to protein electrophoresis. Clinical Significance: While the use of POC analysers is extremely advantageous in small animal primary care facilities, agreement between point‐of‐care and laboratory analysers varies depending on the analyte. For certain analytes, interchangeability of results is limited and specific reference intervals for point‐of‐care analysers are required. Veterinarians should be aware of the size and the direction of the bias of each analyte. … (more)
- Is Part Of:
- Journal of small animal practice. Volume 59:Number 11(2018)
- Journal:
- Journal of small animal practice
- Issue:
- Volume 59:Number 11(2018)
- Issue Display:
- Volume 59, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 11
- Issue Sort Value:
- 2018-0059-0011-0000
- Page Start:
- 704
- Page End:
- 713
- Publication Date:
- 2018-08-01
- Subjects:
- Veterinary medicine -- Periodicals
Veterinary Medicine -- Periodicals
636.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1748-5827 ↗
http://www.blackwell-synergy.com/loi/jsap ↗
http://www.ingentaconnect.com/content/0022-4510 ↗
http://www.ingentaconnect.com/content/bva/jsap ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jsap.12908 ↗
- Languages:
- English
- ISSNs:
- 0022-4510
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5064.700000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23871.xml