Computed tomographic evaluation of three types of screw trajectories for posterior cervical spine fixation: Cervical pedicle screw, lateral mass screw, and paravertebral foramen screw. Issue 28 (15th July 2022)
- Record Type:
- Journal Article
- Title:
- Computed tomographic evaluation of three types of screw trajectories for posterior cervical spine fixation: Cervical pedicle screw, lateral mass screw, and paravertebral foramen screw. Issue 28 (15th July 2022)
- Main Title:
- Computed tomographic evaluation of three types of screw trajectories for posterior cervical spine fixation: Cervical pedicle screw, lateral mass screw, and paravertebral foramen screw
- Authors:
- Tsuda, Keiichi
Tagami, Atsushi
Yamada, Shuta
Yokota, Kazuaki
Chiba, Ko
Yonekura, Akihiko
Tomita, Masato
Osaki, Makoto - Abstract:
- Abstract : Computed tomography (CT) attenuation values of cervical spine were evaluated in vivo using a clinically relevant group. To compare CT attenuation values between cervical pedicle screw (CPS), lateral mass screw (LMS), and paravertebral foramen screw (PVFS) trajectories. CPS and LMS are commonly used for posterior fixation of the cervical spine. The PVFS method has been reported as a new method. CT attenuation values along the screw trajectory are reportedly associated with screw stability. We identified 45 patients who had undergone whole-body CT for trauma with no injury to the cervical spine. Regions of interest (ROIs) were designated along the trajectories that would be used for CPS, LMS, and PVFS through vertebral pedicles and lateral masses of the C3–C6 vertebrae. CT attenuation values of each ROI were measured and compared between each screw trajectories at each cervical vertebral level. Participants were divided into Group I (age, 20–39 years; n = 12), Group II (age, 40–59 years; n = 17), and Group III (age, 60–79 years; n = 16). CT attenuation values of ROIs were compared between each age group. PVFS trajectories showed higher CT attenuation values than LMS trajectories at every vertebral level and also higher values than CPS trajectories at C5 and C6 levels. CT attenuation values at C3 were lower than those at C4 in the LMS trajectory and lower than those at C5 and C6 in the PVFS trajectory. CT attenuation values were lower in the elder group (>60 yearsAbstract : Computed tomography (CT) attenuation values of cervical spine were evaluated in vivo using a clinically relevant group. To compare CT attenuation values between cervical pedicle screw (CPS), lateral mass screw (LMS), and paravertebral foramen screw (PVFS) trajectories. CPS and LMS are commonly used for posterior fixation of the cervical spine. The PVFS method has been reported as a new method. CT attenuation values along the screw trajectory are reportedly associated with screw stability. We identified 45 patients who had undergone whole-body CT for trauma with no injury to the cervical spine. Regions of interest (ROIs) were designated along the trajectories that would be used for CPS, LMS, and PVFS through vertebral pedicles and lateral masses of the C3–C6 vertebrae. CT attenuation values of each ROI were measured and compared between each screw trajectories at each cervical vertebral level. Participants were divided into Group I (age, 20–39 years; n = 12), Group II (age, 40–59 years; n = 17), and Group III (age, 60–79 years; n = 16). CT attenuation values of ROIs were compared between each age group. PVFS trajectories showed higher CT attenuation values than LMS trajectories at every vertebral level and also higher values than CPS trajectories at C5 and C6 levels. CT attenuation values at C3 were lower than those at C4 in the LMS trajectory and lower than those at C5 and C6 in the PVFS trajectory. CT attenuation values were lower in the elder group (>60 years old) than in the other 2 groups for all screw trajectories. CT attenuation values suggested that the PVFS technique may be useful for posterior fixation of the cervical spine in elder patients who require more secure fixation. … (more)
- Is Part Of:
- Medicine. Volume 101:Issue 28(2022)
- Journal:
- Medicine
- Issue:
- Volume 101:Issue 28(2022)
- Issue Display:
- Volume 101, Issue 28 (2022)
- Year:
- 2022
- Volume:
- 101
- Issue:
- 28
- Issue Sort Value:
- 2022-0101-0028-0000
- Page Start:
- e29857
- Page End:
- Publication Date:
- 2022-07-15
- Subjects:
- cervical pedicle screw -- CT attenuation values -- lateral mass screw -- paravertebral foramen screw
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000029857 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23836.xml