Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion. (March 2015)
- Record Type:
- Journal Article
- Title:
- Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion. (March 2015)
- Main Title:
- Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion
- Authors:
- Zhang, Yongbin
Yang, Jinzhong
Zhang, Lifei
Court, Laurence E.
Gao, Song
Balter, Peter A.
Dong, Lei - Abstract:
- Highlights: By taking advantages of deformable image registration, we can successfully convert a single a low-quality cone-beam CT into a high-quality multi-phase cone-beam CT images. Abstract: Conventional in-room cone-beam computed tomography (CBCT) lacks explicit representation of patient respiratory motion and usually has poor image quality and inaccurate CT numbers for target delineation and/or adaptive treatment planning. In-room four-dimensional (4D) CBCT image acquisition is still time consuming and suffers the same issue of poor image quality. To overcome this limitation, we developed a computational framework to digitally synthesize high-quality daily 4D CBCT images using the prior knowledge of motion and appearance learned from the planning 4D CT dataset. A patient-specific respiratory motion model was first constructed from the planning 4D CT images using principal component analysis of displacement vector fields across different respiratory phases. Subsequently, the respiratory motion model as well as the image content of the planning CT was spatially mapped onto the daily CBCT using deformable image registration. The synthesized 4D images possess explicit patient motion while maintaining the geometric accuracy of patient's anatomy at the time of treatment. We validated our model by quantitatively comparing the synthesized 4D CBCT against the 4D CT dataset acquired in the same day from protocol patients undergoing daily in-room CBCT setup and weekly 4D CT forHighlights: By taking advantages of deformable image registration, we can successfully convert a single a low-quality cone-beam CT into a high-quality multi-phase cone-beam CT images. Abstract: Conventional in-room cone-beam computed tomography (CBCT) lacks explicit representation of patient respiratory motion and usually has poor image quality and inaccurate CT numbers for target delineation and/or adaptive treatment planning. In-room four-dimensional (4D) CBCT image acquisition is still time consuming and suffers the same issue of poor image quality. To overcome this limitation, we developed a computational framework to digitally synthesize high-quality daily 4D CBCT images using the prior knowledge of motion and appearance learned from the planning 4D CT dataset. A patient-specific respiratory motion model was first constructed from the planning 4D CT images using principal component analysis of displacement vector fields across different respiratory phases. Subsequently, the respiratory motion model as well as the image content of the planning CT was spatially mapped onto the daily CBCT using deformable image registration. The synthesized 4D images possess explicit patient motion while maintaining the geometric accuracy of patient's anatomy at the time of treatment. We validated our model by quantitatively comparing the synthesized 4D CBCT against the 4D CT dataset acquired in the same day from protocol patients undergoing daily in-room CBCT setup and weekly 4D CT for treatment evaluation. Our preliminary results have demonstrated good agreement of contours in different motion phases between the synthesized and acquired scans. Various imaging artifacts were also suppressed and soft-tissue visibility was enhanced. … (more)
- Is Part Of:
- Computerized medical imaging and graphics. Volume 40(2015)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 40(2015)
- Issue Display:
- Volume 40, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 40
- Issue:
- 2015
- Issue Sort Value:
- 2015-0040-2015-0000
- Page Start:
- 30
- Page End:
- 38
- Publication Date:
- 2015-03
- Subjects:
- Deformable image registration -- 4D CT -- CBCT -- Respiratory motion -- Principal component analysis
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2014.10.007 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23860.xml