Cross-company evaluation of the human lymphocyte activation assay. Issue 1 (1st January 2020)
- Record Type:
- Journal Article
- Title:
- Cross-company evaluation of the human lymphocyte activation assay. Issue 1 (1st January 2020)
- Main Title:
- Cross-company evaluation of the human lymphocyte activation assay
- Authors:
- Collinge, Mark
Schneider, Patricia
Li, Dingzhou
Parish, Stanley
Dumont, Carolyne
Freebern, Wendy
Ghanime, Joseph
Guimont-Derochers, Fanny
Langenkamp, Anja
Lebron, Jose
Li, Nianyu
Marban, Celine
Plitnick, Lisa
Wheeler, Jennifer - Abstract:
- Abstract: Nonclinical immunotoxicity evaluation is an important component of safety assessment for pharmaceuticals. One in vitro assay that can be applied in a weight of evidence assessment is the human lymphocyte activation (HuLA) assay, an antigen recall assay, similar in many respects to the in vivo T-cell-dependent antibody response (TDAR) in that cooperation of multiple immune cell types are needed to produce responses. This assay uses human cells and is more amenable than the TDAR to compound ranking and mechanistic studies. The HuLA assay requires less time and drug than TDAR assays, uses a relevant antigen (influenza), reflects a human immune response, and applies principles of the 3Rs to non-clinical safety assessment. Peripheral blood mononuclear cells (PBMC) from flu-immunized donors are re-stimulated with flu-vaccine in the presence of test articles, and proliferation is measured. Published data demonstrate the applicability of the HuLA assay, but it has not been evaluated for reproducibility across testing sites. To evaluate assay reproducibility, scientists from a consortium of institutions conducted the assay in parallel, using a common pool of donor PBMC, influenza vaccine, and known immunosuppressant compounds (cyclosporine A and mycophenolic acid). The HuLA assay was highly reproducible in identification of inhibition of antigen-specific responses, and there was significant agreement across testing sites in the half maximal inhibitory concentration (IC50 )Abstract: Nonclinical immunotoxicity evaluation is an important component of safety assessment for pharmaceuticals. One in vitro assay that can be applied in a weight of evidence assessment is the human lymphocyte activation (HuLA) assay, an antigen recall assay, similar in many respects to the in vivo T-cell-dependent antibody response (TDAR) in that cooperation of multiple immune cell types are needed to produce responses. This assay uses human cells and is more amenable than the TDAR to compound ranking and mechanistic studies. The HuLA assay requires less time and drug than TDAR assays, uses a relevant antigen (influenza), reflects a human immune response, and applies principles of the 3Rs to non-clinical safety assessment. Peripheral blood mononuclear cells (PBMC) from flu-immunized donors are re-stimulated with flu-vaccine in the presence of test articles, and proliferation is measured. Published data demonstrate the applicability of the HuLA assay, but it has not been evaluated for reproducibility across testing sites. To evaluate assay reproducibility, scientists from a consortium of institutions conducted the assay in parallel, using a common pool of donor PBMC, influenza vaccine, and known immunosuppressant compounds (cyclosporine A and mycophenolic acid). The HuLA assay was highly reproducible in identification of inhibition of antigen-specific responses, and there was significant agreement across testing sites in the half maximal inhibitory concentration (IC50 ) values. Intra-site variability was the largest contributor to the variability observed within the assay. The HuLA assay was demonstrated to be ideally suited to comparing multiple compounds (i.e. compound ranking or benchmarking) within the same assay. Overall, the data reported herein support the HuLA assay as a useful tool in mechanistic evaluations of antigen-specific immune responses. … (more)
- Is Part Of:
- Journal of immunotoxicology. Volume 17:Issue 1(2020)
- Journal:
- Journal of immunotoxicology
- Issue:
- Volume 17:Issue 1(2020)
- Issue Display:
- Volume 17, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2020-0017-0001-0000
- Page Start:
- 51
- Page End:
- 58
- Publication Date:
- 2020-01-01
- Subjects:
- Immune -- in vitro assay -- influenza -- immunosuppression -- PBMC -- cyclosporine -- mycophenolate
Immunotoxicology -- Periodicals
Poisons -- Immunology -- Periodicals
Environmental health -- Periodicals
616.97 - Journal URLs:
- http://informahealthcare.com ↗
- DOI:
- 10.1080/1547691X.2020.1725694 ↗
- Languages:
- English
- ISSNs:
- 1547-691X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5005.043000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23862.xml