Preparation and characterisation of IAEA‐603, a new primary reference material aimed at the VPDB scale realisation for δ13C and δ18O determination. (27th August 2020)
- Record Type:
- Journal Article
- Title:
- Preparation and characterisation of IAEA‐603, a new primary reference material aimed at the VPDB scale realisation for δ13C and δ18O determination. (27th August 2020)
- Main Title:
- Preparation and characterisation of IAEA‐603, a new primary reference material aimed at the VPDB scale realisation for δ13C and δ18O determination
- Authors:
- Assonov, Sergey
Groening, Manfred
Fajgelj, Ales
Hélie, Jean‐Francois
Hillaire‐Marcel, Claude - Abstract:
- Abstract : Rationale: NBS19 carbonate, a primary reference material (RM) for the Vienna Pee Dee Belemnite (VPDB) scale realisation introduced in 1987, was exhausted in 2009, and no primary RM was available for several years. This study describes the preparation and characterisation of a new RM, IAEA‐603 (Ca‐carbonate, calcite of marble origin), which shall serve as a new primary RM (replacement for NBS19) or primary calibrator aimed at the highest realisation of the VPDB scale for δ 13 C and δ 18 O values, including the VPDB‐CO2 δ 18 O scale. Methods: IAEA‐603 preparation and characterisation (value transfer) against NBS19 were performed by addressing the major modern technical requirements for the production and characterisation of RMs (ISO Guide 35). IAEA‐603 was produced in a large quantity, and the first batch was sealed into ampoules (0.5 g) to ensure RM integrity during storage; four other batches were sealed for long‐term storage. The most accurate method of CO2 preparation for isotope mass spectrometry was used, namely carbonate–H3 PO4 reaction under controlled conditions. Results: The assigned values of δ 13 C = +2.460 ± 0.010‰ and δ 18 O = −2.370 ± 0.040‰ ( k = 1) are based on a large number of analyses (~10 mg aliquots) performed at IAEA and address all the known uncertainty components. For aliquots down to 120 μg, the δ 18 O uncertainty remains unchanged but shall be doubled for δ 13 C. The uncertainty components considered are as follows: (a) materialAbstract : Rationale: NBS19 carbonate, a primary reference material (RM) for the Vienna Pee Dee Belemnite (VPDB) scale realisation introduced in 1987, was exhausted in 2009, and no primary RM was available for several years. This study describes the preparation and characterisation of a new RM, IAEA‐603 (Ca‐carbonate, calcite of marble origin), which shall serve as a new primary RM (replacement for NBS19) or primary calibrator aimed at the highest realisation of the VPDB scale for δ 13 C and δ 18 O values, including the VPDB‐CO2 δ 18 O scale. Methods: IAEA‐603 preparation and characterisation (value transfer) against NBS19 were performed by addressing the major modern technical requirements for the production and characterisation of RMs (ISO Guide 35). IAEA‐603 was produced in a large quantity, and the first batch was sealed into ampoules (0.5 g) to ensure RM integrity during storage; four other batches were sealed for long‐term storage. The most accurate method of CO2 preparation for isotope mass spectrometry was used, namely carbonate–H3 PO4 reaction under controlled conditions. Results: The assigned values of δ 13 C = +2.460 ± 0.010‰ and δ 18 O = −2.370 ± 0.040‰ ( k = 1) are based on a large number of analyses (~10 mg aliquots) performed at IAEA and address all the known uncertainty components. For aliquots down to 120 μg, the δ 18 O uncertainty remains unchanged but shall be doubled for δ 13 C. The uncertainty components considered are as follows: (a) material homogeneity (within and between the 5200 ampoules produced), (b) value assignment against NBS19, (c) storage effects and (d) effect of the 17 O correction. Conclusions: The new primary RM IAEA‐603 replaces NBS19 in its use as the highest calibrator for the VPDB δ 13 C and δ 18 O scale, including the VPDB‐CO2 δ 18 O scale. The use of IAEA‐603 will allow laboratories worldwide to establish consistent realisation of the scales for δ 13 C and δ 18 O values and metrological comparability of measurement results for decades. The VPDB scale definition based on NBS19 stays valid. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 34:Number 20(2020)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 34:Number 20(2020)
- Issue Display:
- Volume 34, Issue 20 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 20
- Issue Sort Value:
- 2020-0034-0020-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-08-27
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.8867 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23854.xml