Efficacy of the compensatory reserve measurement in an emergency department trauma population. Issue Volume 61:Issue S1 (2021)Supplement (16th July 2021)
- Record Type:
- Journal Article
- Title:
- Efficacy of the compensatory reserve measurement in an emergency department trauma population. Issue Volume 61:Issue S1 (2021)Supplement (16th July 2021)
- Main Title:
- Efficacy of the compensatory reserve measurement in an emergency department trauma population
- Authors:
- Schauer, Steven G.
April, Michael D.
Arana, Allyson A.
Maddry, Joseph K.
Escandon, Mireya A.
Linscomb, Carlissa D.
Rodriguez, Dylan C.
Convertino, Victor A. - Other Names:
- Yazer Mark H. guestEditor.
Watts Sarah A. guestEditor.
Woolley Col Tom guestEditor. - Abstract:
- Abstract: Background: The Compensatory Reserve Measurement (CRM) is a novel method used to provide early assessment of shock based on arterial wave form morphology changes. We hypothesized that (1) CRM would be significantly lower in those trauma patients who received life‐saving interventions compared with those not receiving interventions, and (2) CRM in patients who received interventions would recover after the intervention was performed. Study design and methods: We captured vital signs along with analog arterial waveform data from trauma patients meeting major activation criteria using a prospective study design. Study team members tracked interventions throughout their emergency department stay. Results: Ninety subjects met inclusion with 13 receiving a blood product and 10 a major airway intervention. Most trauma was blunt (69%) with motor vehicle collisions making up the largest proportion (37%) of injury mechanism. Patients receiving blood products had lower CRM values just prior to administration versus those who did not (50% versus 58%, p = .045), and lower systolic pressure (SBP; 95 versus 123 mmHg, p = .005), diastolic (DBP; 62 versus 79, p = .007), and mean arterial pressure (MAP; 75 versus 95, p = .006), and a higher pulse rate (HR; 101 versus 89 bpm, p = .039). Patients receiving an airway intervention had lower CRM values just prior to administration versus those who did not (48% versus 58%, p = .062); however, SBP, DBP, MAP, and HR were notAbstract: Background: The Compensatory Reserve Measurement (CRM) is a novel method used to provide early assessment of shock based on arterial wave form morphology changes. We hypothesized that (1) CRM would be significantly lower in those trauma patients who received life‐saving interventions compared with those not receiving interventions, and (2) CRM in patients who received interventions would recover after the intervention was performed. Study design and methods: We captured vital signs along with analog arterial waveform data from trauma patients meeting major activation criteria using a prospective study design. Study team members tracked interventions throughout their emergency department stay. Results: Ninety subjects met inclusion with 13 receiving a blood product and 10 a major airway intervention. Most trauma was blunt (69%) with motor vehicle collisions making up the largest proportion (37%) of injury mechanism. Patients receiving blood products had lower CRM values just prior to administration versus those who did not (50% versus 58%, p = .045), and lower systolic pressure (SBP; 95 versus 123 mmHg, p = .005), diastolic (DBP; 62 versus 79, p = .007), and mean arterial pressure (MAP; 75 versus 95, p = .006), and a higher pulse rate (HR; 101 versus 89 bpm, p = .039). Patients receiving an airway intervention had lower CRM values just prior to administration versus those who did not (48% versus 58%, p = .062); however, SBP, DBP, MAP, and HR were not statistically distinguishable ( p ≥ .645). Conclusions: Our results support our hypotheses that the CRM distinguished those patients who received blood or an airway intervention from those who did not, and increased appropriately after interventions were performed. … (more)
- Is Part Of:
- Transfusion. Volume 61:Issue S1 (2021)Supplement
- Journal:
- Transfusion
- Issue:
- Volume 61:Issue S1 (2021)Supplement
- Issue Display:
- Volume 61, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 61
- Issue:
- 2021
- Issue Sort Value:
- 2021-0061-2021-0000
- Page Start:
- S174
- Page End:
- S182
- Publication Date:
- 2021-07-16
- Subjects:
- airway -- blood -- compensatory -- emergency -- reserve -- resuscitation -- trauma
Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.16498 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23860.xml