3D microcalcification detection using a color Doppler twinkling artifact with optimized transmit conditions: Preliminary results. Issue 12 (19th October 2020)
- Record Type:
- Journal Article
- Title:
- 3D microcalcification detection using a color Doppler twinkling artifact with optimized transmit conditions: Preliminary results. Issue 12 (19th October 2020)
- Main Title:
- 3D microcalcification detection using a color Doppler twinkling artifact with optimized transmit conditions: Preliminary results
- Authors:
- Kang, Jinbum
Han, Kanghee
Kim, Kang‐Sik
Jang, Won Seuk
Kim, Min Jung
Yoo, Yangmo - Abstract:
- Abstract : Purpose: Mammography is the only method that has been proven to detect breast microcalcifications (MCs), but the sensitivity of mammography varies according to breast density. This paper proposes an ultrasound (US) color Doppler twinkling artifact (CDTA) method with optimized transmit conditions to identify breast MCs without ionizing radiation. Methods: The transmit conditions for US color Doppler imaging (CDI) were optimized to enhance the sensitivity of the twinkling artifact (TA) that arises from random scattering on rough surfaces of breast MCs. To validate the proposed breast MC detection method, a chicken breast phantom with MC particles (groups of particles <400 μ m and <240 μ m ) was fabricated and scanned by a digital mammography system and an US research platform by an L11‐5v linear array probe with a three‐dimensional (3D) motion tracking system. Results: From the phantom experiment, the proposed 3D CDTA imaging method with optimized transmit conditions (i.e., a center frequency of 5.0 MHz, an f‐number of 1.3, and a peak negative pressure of 1.83 MPa) successfully detected all 16 MC particles, comparable to detection with mammography. For a human breast surgical specimen in the ex vivo study, all 10 MC clusters, marked by a radiologist on the mammogram, were identified with the proposed 3D CDTA imaging method. Conclusions: In the phantom and ex vivo breast specimen studies, the proposed 3D CDTA imaging method successfully detected MCs, and theAbstract : Purpose: Mammography is the only method that has been proven to detect breast microcalcifications (MCs), but the sensitivity of mammography varies according to breast density. This paper proposes an ultrasound (US) color Doppler twinkling artifact (CDTA) method with optimized transmit conditions to identify breast MCs without ionizing radiation. Methods: The transmit conditions for US color Doppler imaging (CDI) were optimized to enhance the sensitivity of the twinkling artifact (TA) that arises from random scattering on rough surfaces of breast MCs. To validate the proposed breast MC detection method, a chicken breast phantom with MC particles (groups of particles <400 μ m and <240 μ m ) was fabricated and scanned by a digital mammography system and an US research platform by an L11‐5v linear array probe with a three‐dimensional (3D) motion tracking system. Results: From the phantom experiment, the proposed 3D CDTA imaging method with optimized transmit conditions (i.e., a center frequency of 5.0 MHz, an f‐number of 1.3, and a peak negative pressure of 1.83 MPa) successfully detected all 16 MC particles, comparable to detection with mammography. For a human breast surgical specimen in the ex vivo study, all 10 MC clusters, marked by a radiologist on the mammogram, were identified with the proposed 3D CDTA imaging method. Conclusions: In the phantom and ex vivo breast specimen studies, the proposed 3D CDTA imaging method successfully detected MCs, and the spatial localization was highly correlated with the mammogram results. These results indicate that the proposed 3D CDTA imaging method has great potential for the detection of MCs without ionizing radiation. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 12(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 12(2020)
- Issue Display:
- Volume 47, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 12
- Issue Sort Value:
- 2020-0047-0012-0000
- Page Start:
- 6171
- Page End:
- 6178
- Publication Date:
- 2020-10-19
- Subjects:
- 3D volume reconstruction -- color Doppler twinkling artifact -- human breast surgical specimen -- mammography -- microcalcification
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14342 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23816.xml