Driveline damage and repair in continuous‐flow left ventricular assist devices: A systematic review. Issue 8 (22nd February 2021)
- Record Type:
- Journal Article
- Title:
- Driveline damage and repair in continuous‐flow left ventricular assist devices: A systematic review. Issue 8 (22nd February 2021)
- Main Title:
- Driveline damage and repair in continuous‐flow left ventricular assist devices: A systematic review
- Authors:
- D'Antonio, Nicholas D.
Maynes, Elizabeth J.
Tatum, Robert T.
Prochno, Kyle W.
Saxena, Abhiraj
Maltais, Simon
Samuels, Louis E.
Morris, Rohinton J.
Massey, H. Todd
Tchantchaleishvili, Vakhtang - Abstract:
- Abstract: With mounting time on continuous‐flow left ventricular assist device (CF‐LVAD) support, patients occasionally sustain damage to the device driveline. Outcomes associated with external and internal driveline damage and repair are currently not well documented. We sought to evaluate the outcomes of driveline damage and its repair. Electronic search was performed to identify all relevant studies published over the past 20 years. Fifteen studies were selected for analysis comprising of 55 patients with CF‐LVAD dysfunction due to driveline damage. Demographic and perioperative variables along with outcomes including survival rates were extracted and pooled for the systematic review. Most patients (53/55) were supported on HeartMate II LVAD (Abbott Laboratories, Abbott Park, IL). Internal damage was more commonly reported than external damage [69.1% (38/55) vs. 30.9% (17/55), P = .01]. Median time to driveline damage was 1.9 years [IQR 1.0, 2.5]. Most patients presented with a CF‐LVAD alarm [94.5% (52/55)] and patients with internal driveline damage had a significantly higher rate of alarm activation compared to that observed for those with external damage [38/38 (100%) vs. 14/17 (82.4%), P = .04]. Patients with internal driveline dysfunction were more likely to experience component wear compared to those with external driveline dysfunction [10/38 (26.3%) vs. 0/17 (0%), P = .05]; 14.5% of patients (8/55) underwent external repair of the driveline, 5.5% (3/55) wereAbstract: With mounting time on continuous‐flow left ventricular assist device (CF‐LVAD) support, patients occasionally sustain damage to the device driveline. Outcomes associated with external and internal driveline damage and repair are currently not well documented. We sought to evaluate the outcomes of driveline damage and its repair. Electronic search was performed to identify all relevant studies published over the past 20 years. Fifteen studies were selected for analysis comprising of 55 patients with CF‐LVAD dysfunction due to driveline damage. Demographic and perioperative variables along with outcomes including survival rates were extracted and pooled for the systematic review. Most patients (53/55) were supported on HeartMate II LVAD (Abbott Laboratories, Abbott Park, IL). Internal damage was more commonly reported than external damage [69.1% (38/55) vs. 30.9% (17/55), P = .01]. Median time to driveline damage was 1.9 years [IQR 1.0, 2.5]. Most patients presented with a CF‐LVAD alarm [94.5% (52/55)] and patients with internal driveline damage had a significantly higher rate of alarm activation compared to that observed for those with external damage [38/38 (100%) vs. 14/17 (82.4%), P = .04]. Patients with internal driveline dysfunction were more likely to experience component wear compared to those with external driveline dysfunction [10/38 (26.3%) vs. 0/17 (0%), P = .05]; 14.5% of patients (8/55) underwent external repair of the driveline, 5.5% (3/55) were treated with rescue tape, and 5.5% (3/55) were placed on an ungrounded cable, indicating a short‐to‐shield event had occurred. A total of 49.1% of patients (27/55) underwent CF‐LVAD exchange, 5.5% (3/55) were weaned off the CF‐LVAD to explant, and 5.5% (3/55) underwent emergent heart transplantation. The median length of hospital stay was 12 days [IQR 7, 12] and 30‐day mortality rate was 14.5% (8/55). Driveline damage was more commonly reported at an internal location and despite being a well‐recognized complication, mortality still appears high. Abstract : Initial management of CF‐LVAD driveline damage. … (more)
- Is Part Of:
- Artificial organs. Volume 45:Issue 8(2021)
- Journal:
- Artificial organs
- Issue:
- Volume 45:Issue 8(2021)
- Issue Display:
- Volume 45, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 45
- Issue:
- 8
- Issue Sort Value:
- 2021-0045-0008-0000
- Page Start:
- 819
- Page End:
- 826
- Publication Date:
- 2021-02-22
- Subjects:
- continuous‐flow left ventricular assist device driveline -- device malfunction -- driveline damage -- driveline infection -- driveline repair -- heart transplant
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.13901 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23795.xml