FEASIBILITY OF DETECTING MYOCARDIAL ISCHAEMIA USING THREE-DIMENSIONAL SPECKLE-TRACKING ECHOCARDIOGRAPHY. (8th October 2012)
- Record Type:
- Journal Article
- Title:
- FEASIBILITY OF DETECTING MYOCARDIAL ISCHAEMIA USING THREE-DIMENSIONAL SPECKLE-TRACKING ECHOCARDIOGRAPHY. (8th October 2012)
- Main Title:
- FEASIBILITY OF DETECTING MYOCARDIAL ISCHAEMIA USING THREE-DIMENSIONAL SPECKLE-TRACKING ECHOCARDIOGRAPHY
- Authors:
- Chen, Li
Chun-mei, Li
Wen-juan, Bai
Xiao-ling, Zhang
Hong, Tang
Li, Rao - Abstract:
- Abstract : Objectives: Strain imaging provides objective quantification of myocardium deformation, thus is a useful tool to detecting regional wall motion abnormalities caused by myocardial ischaemia. With the technologic advancement in real-time three-dimensional echocardiography, the three-dimensional speckle tracking echocardiography (3DSTE) based on high quality volume image has been developed very recently. We aim to investigate the value of the novel 3DSTE in detecting myocardial ischaemia. Methods: Forty-six patients with acute coronary syndrome were included and received coronary angiography (CAG). Patients were divided into myocardial ischaemia group (with >70% coronary stenosis in at least one main branch) and control group (without >70% coronary stenosis) according to the results of (CAG). The conventional and 3D echocardiography was performed using a Vivid E9 ultrasound diagnosis platform (GE Vingmed Ultrasound, Chicago, US). Echo parameters were compared between groups. Ischaemic myocardium segments were defined as territory of coronary arteries with >70% luminal stenosis. ROC curve analysis was performed to evaluate the accuracy of wall motion score (WMS) and strain parameters for detecting ischaemic segments. Results: CAG results showed 26 out of 46 patients had >70% coronary artery stenosis. Speckle tracking were achieved in 94.8% (741/782) segments, with a total of 102 segments classified as ischaemic. The myocardial ischaemia group had significantly lowerAbstract : Objectives: Strain imaging provides objective quantification of myocardium deformation, thus is a useful tool to detecting regional wall motion abnormalities caused by myocardial ischaemia. With the technologic advancement in real-time three-dimensional echocardiography, the three-dimensional speckle tracking echocardiography (3DSTE) based on high quality volume image has been developed very recently. We aim to investigate the value of the novel 3DSTE in detecting myocardial ischaemia. Methods: Forty-six patients with acute coronary syndrome were included and received coronary angiography (CAG). Patients were divided into myocardial ischaemia group (with >70% coronary stenosis in at least one main branch) and control group (without >70% coronary stenosis) according to the results of (CAG). The conventional and 3D echocardiography was performed using a Vivid E9 ultrasound diagnosis platform (GE Vingmed Ultrasound, Chicago, US). Echo parameters were compared between groups. Ischaemic myocardium segments were defined as territory of coronary arteries with >70% luminal stenosis. ROC curve analysis was performed to evaluate the accuracy of wall motion score (WMS) and strain parameters for detecting ischaemic segments. Results: CAG results showed 26 out of 46 patients had >70% coronary artery stenosis. Speckle tracking were achieved in 94.8% (741/782) segments, with a total of 102 segments classified as ischaemic. The myocardial ischaemia group had significantly lower LVEF (66.1%±6.6% vs 49.8%±12.0%, p<0.001) and higher WMS index (1.01±0.03 vs 1.24±0.32, p=0.003) compared with control group. As for the strain parameters, global longitudinal strain (LS), circumferential strain (CS), radial strain (RS) and area strain (AS) were all impaired in myocardial ischaemia group (Global LS: −19.1%±3.1% vs −15.1%±3.2%, p<0.001; Global CS: −18.3%±2.5% vs −15.0%±3.0%, p<0.001; Global RS: 53.7%±10.3% vs 41.2%±9.6%, p<0.001; Global AS: −33.1%±4.1% vs −27.0%±5.2%, p<0.001;). ROC curve analysis showed the sensitivity and specificity of conventional WMS to detect myocardial ischaemia is 54.9% and 93.3%, with an area under curve (AUC) of 0.744. All four strain parameters measured by 3DSTE were proved useful in detecting myocardial ischemia (LS: sensitivity 67.6%, specificity 78.7%, AUC 0.827; CS: sensitivity 72.5%, specificity 78.2%, AUC 0.827; RS: sensitivity 81.4%, specificity 82.6%, AUC 0.886; AS: sensitivity 83.3%, specificity 84.5%, AUC 0.905), with the novel AS yield the highest accuracy. Conclusions: The novel AS derived by 3DSTE is a very accurate and reproducible index for detecting regional wall motion abnormalities caused by myocardial ischaemia. … (more)
- Is Part Of:
- Heart. Volume 98(2012)Supplement 2
- Journal:
- Heart
- Issue:
- Volume 98(2012)Supplement 2
- Issue Display:
- Volume 98, Issue 2 (2012)
- Year:
- 2012
- Volume:
- 98
- Issue:
- 2
- Issue Sort Value:
- 2012-0098-0002-0000
- Page Start:
- E181
- Page End:
- E182
- Publication Date:
- 2012-10-08
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2012-302920k.2 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23770.xml