Arrhythmogenic syncope leading to cardiac rhythm management procedures during COVID-19 lockdown. (1st November 2020)
- Record Type:
- Journal Article
- Title:
- Arrhythmogenic syncope leading to cardiac rhythm management procedures during COVID-19 lockdown. (1st November 2020)
- Main Title:
- Arrhythmogenic syncope leading to cardiac rhythm management procedures during COVID-19 lockdown
- Authors:
- Russo, Vincenzo
Pafundi, Pia Clara
Rapacciuolo, Antonio
D'Andrea, Antonello
de Devitiis, Marcello
Volpicelli, Mario
Ruocco, Antonio
Nigro, Gerardo
D'Onofrio, Antonio - Abstract:
- ABSTRACT: Introduction : Following the coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess admission rate for syncope leading to cardiac rhythm management (CRM) procedures in Campania, the third-most-populous region of Italy, during COVID-19 lockdown. Methods : Data were sourced from 14 referral hospitals in Campania from 10 th March to 4 May 2020 (lockdown period) and during the same period in 2019. Among consecutive patients hospitalized for CRM procedures during the two observational periods, we retrospectively evaluated those admitted for arrhythmogenic syncope. Admission rate and the type of hospital admission between the two observational periods were compared. Results : Among 951 consecutive patients hospitalized for CRM procedures, 204 were admitted for arrhythmogenic syncope leading to CRM procedures. A significant increase in admission was shown in 2020 compared to 2019 (26.4% vs. 18.3%; P = 0.003 ). Moreover, regarding the type of admission to hospitals, attendance at the emergency department (ED) significantly increased (83.5% vs. 56.1%; P < 0.001 ); conversely, a significant decrease in urgent unplanned hospitalizations (6.2% vs. 35.5%; P < 0.001 ) was observed during COVID-19 lockdown. Conclusions : The hospitalization for arrhythmogenic syncope leading to CRM procedures increased during COVID-19 lockdown.
- Is Part Of:
- Expert review of medical devices. Volume 17:Number 11(2020)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 17:Number 11(2020)
- Issue Display:
- Volume 17, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 17
- Issue:
- 11
- Issue Sort Value:
- 2020-0017-0011-0000
- Page Start:
- 1207
- Page End:
- 1210
- Publication Date:
- 2020-11-01
- Subjects:
- Arrhythmias -- cardiac implanted device -- COVID-19 defibrillator -- hospitalization -- pacemaker -- syncope
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2020.1841632 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 23785.xml