Two‐site evaluation of a new workflow for the detection of malignant cells on the Sysmex XN‐1000 body fluid analyzer. (12th March 2020)
- Record Type:
- Journal Article
- Title:
- Two‐site evaluation of a new workflow for the detection of malignant cells on the Sysmex XN‐1000 body fluid analyzer. (12th March 2020)
- Main Title:
- Two‐site evaluation of a new workflow for the detection of malignant cells on the Sysmex XN‐1000 body fluid analyzer
- Authors:
- Favresse, Julien
Boland, Lidvine
Schellen, Marie
Fervaille, Caroline
Wuestenberghs, Fabien
Camboni, Alessandra
Chatelain, Bernard
Mullier, François
Defour, Jean‐Philippe
Jacqmin, Hugues - Abstract:
- Abstract: Introduction: The presence of high fluorescent cells (HF‐BF) on the Sysmex XN‐1000 hematology analyzers has gained interest regarding the prediction of malignant cells in body fluids, but lacks sensitivity. We aimed to increase this sensitivity by combining HF‐BF value, automated results, and clinical information. Methods: We evaluated a new workflow for the management of body fluids in the hematology laboratory, including the HF‐BF criterion and clinical information. In two laboratories, 1623 serous fluids were retrospectively analyzed on the XN‐1000 BF mode. All samples were morphologically screened for malignant cells. Optimal HF‐BF cutoffs were determined to predict their presence. Thereafter, the added value of clinical information was evaluated. Other reflex testing rules (eosinophilic count >5% and presence of the WBC Abnormal Scattergram flag) were also used to refine our workflow. Results: Optimal HF‐BF cutoffs in the two hematology centers were 108 and 45 cells/µL, yielding a sensitivity/specificity of 66.7/93.6% and 86.8/66.6% for malignant cell detection. When adding clinical information, sensitivity/specificity evolved to 100.0/68.9% and 100.0%/not determined. Of 104 samples containing malignant cells, 97 had positive clinical information; the remainder had a HF‐BF > cutoff. Conclusion: Combining clinical information and HF‐BF reached 100% sensitivity for malignant cell detection in body fluid analysis. Lack of robustness of the optimal HF‐BF cutoffAbstract: Introduction: The presence of high fluorescent cells (HF‐BF) on the Sysmex XN‐1000 hematology analyzers has gained interest regarding the prediction of malignant cells in body fluids, but lacks sensitivity. We aimed to increase this sensitivity by combining HF‐BF value, automated results, and clinical information. Methods: We evaluated a new workflow for the management of body fluids in the hematology laboratory, including the HF‐BF criterion and clinical information. In two laboratories, 1623 serous fluids were retrospectively analyzed on the XN‐1000 BF mode. All samples were morphologically screened for malignant cells. Optimal HF‐BF cutoffs were determined to predict their presence. Thereafter, the added value of clinical information was evaluated. Other reflex testing rules (eosinophilic count >5% and presence of the WBC Abnormal Scattergram flag) were also used to refine our workflow. Results: Optimal HF‐BF cutoffs in the two hematology centers were 108 and 45 cells/µL, yielding a sensitivity/specificity of 66.7/93.6% and 86.8/66.6% for malignant cell detection. When adding clinical information, sensitivity/specificity evolved to 100.0/68.9% and 100.0%/not determined. Of 104 samples containing malignant cells, 97 had positive clinical information; the remainder had a HF‐BF > cutoff. Conclusion: Combining clinical information and HF‐BF reached 100% sensitivity for malignant cell detection in body fluid analysis. Lack of robustness of the optimal HF‐BF cutoff deserves the use of local cutoffs. Rapid automated results reporting from the XN‐1000 BF mode are also feasible in clinical practice. Prospective evaluation of the workflow is needed before its implementation in clinical practice. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 42:Number 5(2020:Oct.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 42:Number 5(2020:Oct.)
- Issue Display:
- Volume 42, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2020-0042-0005-0000
- Page Start:
- 544
- Page End:
- 551
- Publication Date:
- 2020-03-12
- Subjects:
- body fluids -- cell count -- malignant cell detection -- reflex testing rules -- Sysmex XN‐1000
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.13187 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23786.xml