Making sense of glucose metrics in diabetes: linkage between postprandial glucose (PPG), time in range (TIR) & hemoglobin A1c (A1C). Issue 3 (3rd April 2021)
- Record Type:
- Journal Article
- Title:
- Making sense of glucose metrics in diabetes: linkage between postprandial glucose (PPG), time in range (TIR) & hemoglobin A1c (A1C). Issue 3 (3rd April 2021)
- Main Title:
- Making sense of glucose metrics in diabetes: linkage between postprandial glucose (PPG), time in range (TIR) & hemoglobin A1c (A1C)
- Authors:
- Martens, Thomas W
Bergenstal, Richard M
Pearson, Teresa
Carlson, Anders L
Scheiner, Gary
Carlos, Campos
Liao, Birong
Syring, Kristen
Pollom, Roy Daniel - Abstract:
- ABSTRACT: While A1C is the standard diagnostic test for evaluating long-term glucose management, additional glucose data, either from fingerstick blood glucose testing, or more recently, continuous glucose monitoring (CGM), is necessary for safe and effective management of diabetes, especially for individuals treated with insulin. CGM technology and retrospective pattern-based management using various CGM reports have the potential to improve glycemic management beyond what is possible with fingerstick blood glucose monitoring. CGM software can provide valuable retrospective data on Time-in-Ranges (above, below, within) metrics, the Ambulatory Glucose Profile (AGP), overlay reports, and daily views for persons with diabetes and their healthcare providers. This data can aid in glycemic pattern identification and evaluation of the impact of lifestyle factors on these patterns. Time-in-Ranges data provide an easy-to-define metric that can facilitate goal setting discussions between clinicians and persons with diabetes to improve glycemic management and can empower persons with diabetes in self-management between clinic consultation visits. Here we discuss multiple real-life scenarios from a primary care clinic for the application of CGM in persons with diabetes. Optimizing the use of the reports generated by CGM software, with attention to time in range, time below range, and postprandial glucose-induced time above range, can improve the safety and efficacy of ongoing glucoseABSTRACT: While A1C is the standard diagnostic test for evaluating long-term glucose management, additional glucose data, either from fingerstick blood glucose testing, or more recently, continuous glucose monitoring (CGM), is necessary for safe and effective management of diabetes, especially for individuals treated with insulin. CGM technology and retrospective pattern-based management using various CGM reports have the potential to improve glycemic management beyond what is possible with fingerstick blood glucose monitoring. CGM software can provide valuable retrospective data on Time-in-Ranges (above, below, within) metrics, the Ambulatory Glucose Profile (AGP), overlay reports, and daily views for persons with diabetes and their healthcare providers. This data can aid in glycemic pattern identification and evaluation of the impact of lifestyle factors on these patterns. Time-in-Ranges data provide an easy-to-define metric that can facilitate goal setting discussions between clinicians and persons with diabetes to improve glycemic management and can empower persons with diabetes in self-management between clinic consultation visits. Here we discuss multiple real-life scenarios from a primary care clinic for the application of CGM in persons with diabetes. Optimizing the use of the reports generated by CGM software, with attention to time in range, time below range, and postprandial glucose-induced time above range, can improve the safety and efficacy of ongoing glucose management. Abstract : … (more)
- Is Part Of:
- Postgraduate medicine. Volume 133:Issue 3(2021)
- Journal:
- Postgraduate medicine
- Issue:
- Volume 133:Issue 3(2021)
- Issue Display:
- Volume 133, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 133
- Issue:
- 3
- Issue Sort Value:
- 2021-0133-0003-0000
- Page Start:
- 253
- Page End:
- 264
- Publication Date:
- 2021-04-03
- Subjects:
- Diabetes -- CGM -- AGP -- time in range -- glycemic management
Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Periodicals
610.5 - Journal URLs:
- http://www.postgradmed.com/journal.htm ↗
http://www.tandfonline.com/toc/ipgm20/current#.VjJrC_6FOUk ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00325481.2020.1851946 ↗
- Languages:
- English
- ISSNs:
- 0032-5481
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23784.xml