Technical Note: Accuracy of MTF measurements with an edge phantom at megavoltage x‐ray energies. Issue 12 (21st October 2019)
- Record Type:
- Journal Article
- Title:
- Technical Note: Accuracy of MTF measurements with an edge phantom at megavoltage x‐ray energies. Issue 12 (21st October 2019)
- Main Title:
- Technical Note: Accuracy of MTF measurements with an edge phantom at megavoltage x‐ray energies
- Authors:
- Loot, Katharina
Block, Andreas - Abstract:
- Abstract : Purpose: Measurement of the modulation transfer function (MTF) is performed by evaluating the response of an imaging system to a predefined input. To obtain accurate results when using an edge phantom, the detector input signal must resemble an ideal step function. The MTF of megavoltage (MV) imagers used in radiotherapy has been measured with highly absorbing edge phantoms fabricated from thick metal blocks. This study investigates the influence of the edge phantom design on the accuracy of the resulting MTF. Methods: The MTF of an electronic portal imaging device (EPID) was measured at 6 MV beam quality with four edge phantoms made of lead with 1.3, 3.3, 5.0, and 10.0 cm thickness. Monte Carlo simulations were carried out for these and a selection of tungsten phantoms to determine the photon fluence at the imaging plane and quantify the systematic error in the MTF introduced by the edge phantom design. Results: The measured MTF depends on the design of the edge phantom. The detector input signal of a thin phantom is affected by secondary radiation from the phantom itself, causing an overestimation of the MTF. The amount of secondary radiation can be reduced by increasing the phantom thickness or introducing an air gap between the phantom and the detector. Both methods introduce geometric unsharpness, which can result in an underestimation of the true MTF. Edge phantoms made from 4.0 cm thick tungsten or 5.0 cm thick lead induce comparatively small systematicAbstract : Purpose: Measurement of the modulation transfer function (MTF) is performed by evaluating the response of an imaging system to a predefined input. To obtain accurate results when using an edge phantom, the detector input signal must resemble an ideal step function. The MTF of megavoltage (MV) imagers used in radiotherapy has been measured with highly absorbing edge phantoms fabricated from thick metal blocks. This study investigates the influence of the edge phantom design on the accuracy of the resulting MTF. Methods: The MTF of an electronic portal imaging device (EPID) was measured at 6 MV beam quality with four edge phantoms made of lead with 1.3, 3.3, 5.0, and 10.0 cm thickness. Monte Carlo simulations were carried out for these and a selection of tungsten phantoms to determine the photon fluence at the imaging plane and quantify the systematic error in the MTF introduced by the edge phantom design. Results: The measured MTF depends on the design of the edge phantom. The detector input signal of a thin phantom is affected by secondary radiation from the phantom itself, causing an overestimation of the MTF. The amount of secondary radiation can be reduced by increasing the phantom thickness or introducing an air gap between the phantom and the detector. Both methods introduce geometric unsharpness, which can result in an underestimation of the true MTF. Edge phantoms made from 4.0 cm thick tungsten or 5.0 cm thick lead induce comparatively small systematic errors of below 3% or 5%, respectively. Conclusions: When MTF measurements are conducted at MV energies, even a highly absorbing edge phantom will introduce a systematic error of several percent. Direct comparison of MTFs obtained with different edge phantoms should therefore be treated with caution. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 12(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 12(2019)
- Issue Display:
- Volume 46, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2019-0046-0012-0000
- Page Start:
- 5685
- Page End:
- 5689
- Publication Date:
- 2019-10-21
- Subjects:
- edge method -- megavoltage (MV) x‐ray imaging -- modulation transfer function (MTF) -- portal imaging -- radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13843 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23742.xml