Mitigating inherent noise in Monte Carlo dose distributions using dilated U‐Net. Issue 12 (1st November 2019)
- Record Type:
- Journal Article
- Title:
- Mitigating inherent noise in Monte Carlo dose distributions using dilated U‐Net. Issue 12 (1st November 2019)
- Main Title:
- Mitigating inherent noise in Monte Carlo dose distributions using dilated U‐Net
- Authors:
- Javaid, Umair
Souris, Kevin
Dasnoy, Damien
Huang, Sheng
Lee, John A. - Abstract:
- Abstract : Purpose: Monte Carlo (MC) algorithms offer accurate modeling of dose calculation by simulating the transport and interactions of many particles through the patient geometry. However, given their random nature, the resulting dose distributions have statistical uncertainty (noise), which prevents making reliable clinical decisions. This issue is partly addressable using a huge number of simulated particles but is computationally expensive as it results in significantly greater computation times. Therefore, there is a trade‐off between the computation time and the noise level in MC dose maps. In this work, we address the mitigation of noise inherent to MC dose distributions using dilated U‐Net — an encoder–decoder‐styled fully convolutional neural network, which allows fast and fully automated denoising of whole‐volume dose maps. Methods: We use mean squared error (MSE) as loss function to train the model, where training is done in 2D and 2.5D settings by considering a number of adjacent slices. Our model is trained on proton therapy MC dose distributions of different tumor sites (brain, head and neck, liver, lungs, and prostate) acquired from 35 patients. We provide the network with input MC dose distributions simulated using 1 × 10 6 particles while keeping 1 × 10 9 particles as reference. Results: After training, our model successfully denoises new MC dose maps. On average (averaged over five patients with different tumor sites), our model recovers D 95 ofAbstract : Purpose: Monte Carlo (MC) algorithms offer accurate modeling of dose calculation by simulating the transport and interactions of many particles through the patient geometry. However, given their random nature, the resulting dose distributions have statistical uncertainty (noise), which prevents making reliable clinical decisions. This issue is partly addressable using a huge number of simulated particles but is computationally expensive as it results in significantly greater computation times. Therefore, there is a trade‐off between the computation time and the noise level in MC dose maps. In this work, we address the mitigation of noise inherent to MC dose distributions using dilated U‐Net — an encoder–decoder‐styled fully convolutional neural network, which allows fast and fully automated denoising of whole‐volume dose maps. Methods: We use mean squared error (MSE) as loss function to train the model, where training is done in 2D and 2.5D settings by considering a number of adjacent slices. Our model is trained on proton therapy MC dose distributions of different tumor sites (brain, head and neck, liver, lungs, and prostate) acquired from 35 patients. We provide the network with input MC dose distributions simulated using 1 × 10 6 particles while keeping 1 × 10 9 particles as reference. Results: After training, our model successfully denoises new MC dose maps. On average (averaged over five patients with different tumor sites), our model recovers D 95 of 55.99 Gy from the noisy MC input of 49.51 Gy, whereas the low noise MC (reference) offers 56.03 Gy. We observed a significant reduction in average RMSE (thresholded >10% max ref) for reference vs denoised (1.25 Gy) than reference vs input (16.96 Gy) leading to an improvement in signal‐to‐noise ratio (ISNR) by 18.06 dB. Moreover, the inference time of our model for a dose distribution is less than 10 s vs 100 min (MC simulation using 1 × 10 9 particles). Conclusions: We propose an end‐to‐end fully convolutional network that can denoise Monte Carlo dose distributions. The networks provide comparable qualitative and quantitative results as the MC dose distribution simulated with 1 × 10 9 particles, offering a significant reduction in computation time. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 12(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 12(2019)
- Issue Display:
- Volume 46, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2019-0046-0012-0000
- Page Start:
- 5790
- Page End:
- 5798
- Publication Date:
- 2019-11-01
- Subjects:
- artificial intelligence -- deep learning -- dose denoising -- Monte Carlo -- proton therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13856 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23742.xml