Andrade, Edson R. - Abstract:
- Abstract : Abstract: Medical linear accelerators (linacs) require a physical structure designed to provide adequate structural support which ensures the safety of patients, operators and the general public. During a radiotherapy session, healthy tissues are exposed to radiation, even with these safety guarantees. This unwanted exposure may increase the likelihood of developing secondary cancer. This work uses the MCNP-5 code to computationally simulate a conformational 3D radiotherapy protocol for prostate cancer. Also, it investigates the potential effects of radiotherapy room shielding composition on equivalent and effective doses in the patient's body. A computational model of an actual room was developed considering a Varian Trilogy linac operating at 10 MeV. This model enabled dose calculations for an anthropomorphic phantom called REX to be performed. This phantom has sufficient details of all relevant organs and tissues needed to estimate the effective dose of the patient. The treatment protocol modeled in this study came from the database of patients treated by the Brazilian National Cancer Institute (Inca). For this protocol, the total dose to be applied to the patient is equally distributed over the four gantry inclination angles (0°, 90°, 180° and 270°). The simulated results suggested that the equivalent dose on different organs and tissues has been increased by concrete shielding. Regarding the effective dose due to the presence of additional shielding (steel orAbstract : Abstract: Medical linear accelerators (linacs) require a physical structure designed to provide adequate structural support which ensures the safety of patients, operators and the general public. During a radiotherapy session, healthy tissues are exposed to radiation, even with these safety guarantees. This unwanted exposure may increase the likelihood of developing secondary cancer. This work uses the MCNP-5 code to computationally simulate a conformational 3D radiotherapy protocol for prostate cancer. Also, it investigates the potential effects of radiotherapy room shielding composition on equivalent and effective doses in the patient's body. A computational model of an actual room was developed considering a Varian Trilogy linac operating at 10 MeV. This model enabled dose calculations for an anthropomorphic phantom called REX to be performed. This phantom has sufficient details of all relevant organs and tissues needed to estimate the effective dose of the patient. The treatment protocol modeled in this study came from the database of patients treated by the Brazilian National Cancer Institute (Inca). For this protocol, the total dose to be applied to the patient is equally distributed over the four gantry inclination angles (0°, 90°, 180° and 270°). The simulated results suggested that the equivalent dose on different organs and tissues has been increased by concrete shielding. Regarding the effective dose due to the presence of additional shielding (steel or lead), the simulation suggests that such variations can be considered small. Overall the results allowed quantifying the specific contribution of concrete, lead, and steel as part of shielding on the equivalent and effective doses in the patient. Highlights: The concrete shielding contributes to the increase of the patient's equivalent dose. The contribution of 1 TVL of steel or lead in the primary belt would be irrelevant. The dose portion attributed to shielding is approximately homogeneous outside the treatment region. The equivalent dose for several organs/tissues is impacted by lead/steel shielding. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 163(2020:Sep.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 163(2020:Sep.)
- Issue Display:
- Volume 163 (2020)
- Year:
- 2020
- Volume:
- 163
- Issue Sort Value:
- 2020-0163-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2020.109163 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23758.xml