Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol. Issue 11 (November 2017)
- Record Type:
- Journal Article
- Title:
- Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol. Issue 11 (November 2017)
- Main Title:
- Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol
- Authors:
- Cohen-Hallaleh, V.
Guo, L.
Hosseini-Nik, H.
Razaghi Kashani, N.
Menezes, R.
Jhaveri, K. - Abstract:
- Abstract : Aim: To evaluate retrospectively the impact of injection flow rate on arterial phase image degradation in liver magnetic resonance imaging (MRI) with gadoxetic acid (Gd-EOB-DTPA) compared to gadobutrol. Materials and methods: Two hundred consecutive patients who had undergone liver MRI were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant institutional review board (IRB)-approved study and were divided into three groups. Group 1 (50 patients) and 2 (50 patients) had undergone MRI performed with gadoxetic acid (fixed 10 ml) at flow rate of 1 and 2 ml/s, respectively. Group 3 (100 patients) had undergone MRI performed with gadobutrol (0.1 mmol/kg) at 1 ml/s. Precontrast and post-contrast (arterial, portal venous, and hepatic venous phases) image degradation was assessed by two blinded independent readers using a four-point rating scale. The numbers of patients with arterial phase image degradation were compared using the Fisher exact test among the three groups. Results: The incidence of arterial phase image degradation was 12% (6/50) in group 1 and 16% (8/50) in group 2 for both readers, 6% (6/100) for reader 1 and 5% (5/100) for reader 2 in group 3. Group 2 had a higher incidence of arterial phase image degradation when compared with group 3 for reader 2 ( p =0.032). Severe arterial phase image degradation, resulting in non-diagnostic image quality, occurred in 4% (2/50) of patients when performed with gadoxetic acidAbstract : Aim: To evaluate retrospectively the impact of injection flow rate on arterial phase image degradation in liver magnetic resonance imaging (MRI) with gadoxetic acid (Gd-EOB-DTPA) compared to gadobutrol. Materials and methods: Two hundred consecutive patients who had undergone liver MRI were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant institutional review board (IRB)-approved study and were divided into three groups. Group 1 (50 patients) and 2 (50 patients) had undergone MRI performed with gadoxetic acid (fixed 10 ml) at flow rate of 1 and 2 ml/s, respectively. Group 3 (100 patients) had undergone MRI performed with gadobutrol (0.1 mmol/kg) at 1 ml/s. Precontrast and post-contrast (arterial, portal venous, and hepatic venous phases) image degradation was assessed by two blinded independent readers using a four-point rating scale. The numbers of patients with arterial phase image degradation were compared using the Fisher exact test among the three groups. Results: The incidence of arterial phase image degradation was 12% (6/50) in group 1 and 16% (8/50) in group 2 for both readers, 6% (6/100) for reader 1 and 5% (5/100) for reader 2 in group 3. Group 2 had a higher incidence of arterial phase image degradation when compared with group 3 for reader 2 ( p =0.032). Severe arterial phase image degradation, resulting in non-diagnostic image quality, occurred in 4% (2/50) of patients when performed with gadoxetic acid administration at 2 ml/s and 2% (1/50) at 1 ml/s. Conclusion: A slower injection flow rate has a trend to reduce the incidence and severity of arterial phase image degradation during liver MRI with gadoxetic acid when compared to gadobutrol. Highlights: The incidence of arterial phase image degradation was 16% when Gd-EOB-DTPA (fixed 10 ml) was injected at a flow rate of 2 ml/sec. Severe arterial phase image degradation, resulting in non-diagnostic image quality, occurred in 4% of patients when performed Gd-EOB-DTPA administration at 2 ml/sec. Slower injection flow rate, reduced from 2 ml/sec to 1 ml/sec, has a trend to reduce the incidence and severity of arterial phase image degradation. … (more)
- Is Part Of:
- Clinical radiology. Volume 72:Issue 11(2017)
- Journal:
- Clinical radiology
- Issue:
- Volume 72:Issue 11(2017)
- Issue Display:
- Volume 72, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 72
- Issue:
- 11
- Issue Sort Value:
- 2017-0072-0011-0000
- Page Start:
- 994.e1
- Page End:
- 994.e8
- Publication Date:
- 2017-11
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2017.06.005 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23739.xml