A precast beam-column connection using metallic damper as connector: Experiment and application. (June 2021)
- Record Type:
- Journal Article
- Title:
- A precast beam-column connection using metallic damper as connector: Experiment and application. (June 2021)
- Main Title:
- A precast beam-column connection using metallic damper as connector: Experiment and application
- Authors:
- Li, Dingbin
Wu, Congxiao
Zhou, Yun
Luo, Weili
Lie, Wenchen - Abstract:
- Abstract: The beam-column connection is the most vulnerable part of the precast moment-resisting frame in earthquakes. A novel beam-column connection using a metallic damper is proposed in this paper. Two metallic dampers (a dog-bone (DB) damper and a double-flange (DF) damper) and a suitable connection configuration using channel steel and a U-shaped anchoring unit were introduced. The failure mechanism and mechanical performance of the two dampers were elaborately investigated by a quasi-static test. Test results showed that the flexural strength (81.22 kN·m) and deformation capacity (119.6 mm) of damper DF were better than these of damper DB (64.82 kN·m and 71.8 mm). The cumulative energy absorbed by damper DF was 50.44 kN·m, increasing 69.43% compared with damper DB (29.77 kN·m). The dampers DB and DF were then applied to two proposed connections (PCF-DB and PCF-DF), and a laboratory test was conducted. Test results indicate that the proposed connection was easy to be assembled and disassembled. The plastic damage of the beam-column connections was concentrated in the metallic damper. The connection configuration remained in elastic state. Both in the laboratory tests on damper and proposed connection, the failure pattern of DB was the out-of-plane flexural-torsional buckling while that of DF is the in-plane bending. Graphical abstract: Unlabelled Image Highlights: The beam-column connection is the most vulnerable part of the precast moment-resisting frame inAbstract: The beam-column connection is the most vulnerable part of the precast moment-resisting frame in earthquakes. A novel beam-column connection using a metallic damper is proposed in this paper. Two metallic dampers (a dog-bone (DB) damper and a double-flange (DF) damper) and a suitable connection configuration using channel steel and a U-shaped anchoring unit were introduced. The failure mechanism and mechanical performance of the two dampers were elaborately investigated by a quasi-static test. Test results showed that the flexural strength (81.22 kN·m) and deformation capacity (119.6 mm) of damper DF were better than these of damper DB (64.82 kN·m and 71.8 mm). The cumulative energy absorbed by damper DF was 50.44 kN·m, increasing 69.43% compared with damper DB (29.77 kN·m). The dampers DB and DF were then applied to two proposed connections (PCF-DB and PCF-DF), and a laboratory test was conducted. Test results indicate that the proposed connection was easy to be assembled and disassembled. The plastic damage of the beam-column connections was concentrated in the metallic damper. The connection configuration remained in elastic state. Both in the laboratory tests on damper and proposed connection, the failure pattern of DB was the out-of-plane flexural-torsional buckling while that of DF is the in-plane bending. Graphical abstract: Unlabelled Image Highlights: The beam-column connection is the most vulnerable part of the precast moment-resisting frame in earthquakes. A novel precast beam-column connection using metallic damper as connector was proposed. Two suitable metallic dampers and a connection configuration were introduced. The two metallic dampers were tested and applied to the precast connection. … (more)
- Is Part Of:
- Journal of constructional steel research. Volume 181(2021)
- Journal:
- Journal of constructional steel research
- Issue:
- Volume 181(2021)
- Issue Display:
- Volume 181, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 181
- Issue:
- 2021
- Issue Sort Value:
- 2021-0181-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- Precast concrete frame -- Beam-column connection -- Metallic damper -- Seismic performance -- Quasi-static loading
Steel, Structural -- Periodicals
Building, Iron and steel -- Periodicals
Acier de construction -- Périodiques
Construction métallique -- Périodiques
624.1821 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0143974X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcsr.2021.106628 ↗
- Languages:
- English
- ISSNs:
- 0143-974X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.193000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23751.xml