Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolization. Issue 154 (September 2022)
- Record Type:
- Journal Article
- Title:
- Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolization. Issue 154 (September 2022)
- Main Title:
- Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolization
- Authors:
- Inoue, Akitoshi
Uemura, Ryo
Takaki, Kai
Sonoda, Akinaga
Ota, Shinichi
Nitta, Norihisa
Batsaikhan, Bolorkhand
Takahashi, Hiroaki
Watanabe, Yoshiyuki - Abstract:
- Abstract: Purpose: This study aimed to evaluate the clinical impact of low tube voltage computed tomography (CT) during hepatic arteriography (CTHA) using low iodine contrast to detect hepatocellular carcinoma (HCC). Materials and methods: CTHA images were obtained using a dual-spin technique (80 kVp and 135 kVp) with 30 ml of low-dose iodine contrast (75 mgI/ml). Three radiologists reviewed 135 kVp and 80 kVp CTHA images to diagnose HCC, recording their confidence scores and evaluations of sharpness, noise, artifact, and overall image quality. Lesion-to-liver contrast ratios and objective noise were measured by a non-reader radiologist. Results: We included 23 patients (body mass index, 23.6 ± 2.6 kg/m 2 ) with 89 HCCs. The mean radiation dose index volume was 21.3 mGy at 135 kVp and 9.4 mGy at 80 kVp (P < 0.001). The overall sensitivity and positive predictive value for diagnosing HCCs at 80 kVp vs. 135 kVp were 0.787 vs. 0.730 and 0.712 vs. 0.756, respectively. The lesion-to-liver contrast ratio at 80 kVp was significantly higher than at 135 kVp in the first (3.1 vs. 2.0; P = 0.008) and second phase (3.1 vs. 2.3; P = 0.016). Objective noise was significantly higher at 80 kVp than at 135 kVp in the first (15. 6 ± 4.9 vs. 11.0 ± 3.1; P < 0.001) and second (16.9 ± 5.2 vs. 15.0 ± 7.3; P = 0.046) phases. Conclusion: An 80 kVp CTHA, with lower-dose iodine, improved the sensitivity and reduced the radiation dose, despite a decreased positive predictive value in comparison with aAbstract: Purpose: This study aimed to evaluate the clinical impact of low tube voltage computed tomography (CT) during hepatic arteriography (CTHA) using low iodine contrast to detect hepatocellular carcinoma (HCC). Materials and methods: CTHA images were obtained using a dual-spin technique (80 kVp and 135 kVp) with 30 ml of low-dose iodine contrast (75 mgI/ml). Three radiologists reviewed 135 kVp and 80 kVp CTHA images to diagnose HCC, recording their confidence scores and evaluations of sharpness, noise, artifact, and overall image quality. Lesion-to-liver contrast ratios and objective noise were measured by a non-reader radiologist. Results: We included 23 patients (body mass index, 23.6 ± 2.6 kg/m 2 ) with 89 HCCs. The mean radiation dose index volume was 21.3 mGy at 135 kVp and 9.4 mGy at 80 kVp (P < 0.001). The overall sensitivity and positive predictive value for diagnosing HCCs at 80 kVp vs. 135 kVp were 0.787 vs. 0.730 and 0.712 vs. 0.756, respectively. The lesion-to-liver contrast ratio at 80 kVp was significantly higher than at 135 kVp in the first (3.1 vs. 2.0; P = 0.008) and second phase (3.1 vs. 2.3; P = 0.016). Objective noise was significantly higher at 80 kVp than at 135 kVp in the first (15. 6 ± 4.9 vs. 11.0 ± 3.1; P < 0.001) and second (16.9 ± 5.2 vs. 15.0 ± 7.3; P = 0.046) phases. Conclusion: An 80 kVp CTHA, with lower-dose iodine, improved the sensitivity and reduced the radiation dose, despite a decreased positive predictive value in comparison with a 135-kVp CTHA with the same iodine dose. … (more)
- Is Part Of:
- European journal of radiology. Issue 154(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 154(2022)
- Issue Display:
- Volume 154, Issue 154 (2022)
- Year:
- 2022
- Volume:
- 154
- Issue:
- 154
- Issue Sort Value:
- 2022-0154-0154-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- Computed tomography -- Hepatocellular carcinoma -- Chemoembolization -- Contrast media -- Radiation dosage
BMI body mass index -- CT computed tomography -- CTDIvol CT dose index volume -- CTHA computed tomography during arteriography -- DLP dose-length product -- FROC free-response receiver operating characteristic curves -- HCC hepatocellular carcinoma -- LI-RADS liver imaging reporting and data system -- LLF lesion localization fraction -- NLF non-lesion localization fraction -- PC-AKI post-contrast acute kidney injury -- PPV positive predictive value -- TACE transarterial chemoembolization
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110420 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23709.xml