Periodic-Zone Model Predictive Control for Diurnal Closed-Loop Operation of an Artificial Pancreas. (November 2013)
- Record Type:
- Journal Article
- Title:
- Periodic-Zone Model Predictive Control for Diurnal Closed-Loop Operation of an Artificial Pancreas. (November 2013)
- Main Title:
- Periodic-Zone Model Predictive Control for Diurnal Closed-Loop Operation of an Artificial Pancreas
- Authors:
- Gondhalekar, Ravi
Dassau, Eyal
Zisser, Howard C.
Doyle, Francis J. - Abstract:
- Background: The objective of this research is an artificial pancreas (AP) that performs automatic regulation of blood glucose levels in people with type 1 diabetes mellitus. This article describes a control strategy that performs algorithmic insulin dosing for maintaining safe blood glucose levels over prolonged, overnight periods of time and furthermore was designed with outpatient, multiday deployment in mind. Of particular concern is the prevention of nocturnal hypoglycemia, because during sleep, subjects cannot monitor themselves and may not respond to alarms. An AP intended for prolonged and unsupervised outpatient deployment must strategically reduce the risk of hypoglycemia during times of sleep, without requiring user interaction. Methods: A diurnal insulin delivery strategy based on predictive control methods is proposed. The so-called "periodic-zone model predictive control" (PZMPC) strategy employs periodically time-dependent blood glucose output target zones and furthermore enforces periodically time-dependent insulin input constraints to modulate its behavior based on the time of day. Results: The proposed strategy was evaluated through an extensive simulation-based study and a preliminary clinical trial. Results indicate that the proposed method delivers insulin more conservatively during nighttime than during daytime while maintaining safe blood glucose levels at all times. In clinical trials, the proposed strategy delivered 77% of the amount of insulinBackground: The objective of this research is an artificial pancreas (AP) that performs automatic regulation of blood glucose levels in people with type 1 diabetes mellitus. This article describes a control strategy that performs algorithmic insulin dosing for maintaining safe blood glucose levels over prolonged, overnight periods of time and furthermore was designed with outpatient, multiday deployment in mind. Of particular concern is the prevention of nocturnal hypoglycemia, because during sleep, subjects cannot monitor themselves and may not respond to alarms. An AP intended for prolonged and unsupervised outpatient deployment must strategically reduce the risk of hypoglycemia during times of sleep, without requiring user interaction. Methods: A diurnal insulin delivery strategy based on predictive control methods is proposed. The so-called "periodic-zone model predictive control" (PZMPC) strategy employs periodically time-dependent blood glucose output target zones and furthermore enforces periodically time-dependent insulin input constraints to modulate its behavior based on the time of day. Results: The proposed strategy was evaluated through an extensive simulation-based study and a preliminary clinical trial. Results indicate that the proposed method delivers insulin more conservatively during nighttime than during daytime while maintaining safe blood glucose levels at all times. In clinical trials, the proposed strategy delivered 77% of the amount of insulin delivered by a time-invariant control strategy; specifically, it delivered on average 1.23 U below, compared with 0.31 U above, the nominal basal rate overnight while maintaining comparable, and safe, blood glucose values. Conclusions: The proposed PZMPC algorithm strategically prevents nocturnal hypoglycemia and is considered a significant step toward deploying APs into outpatient environments for extended periods of time in full closed-loop operation. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 7:Number 6(2013)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 7:Number 6(2013)
- Issue Display:
- Volume 7, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 7
- Issue:
- 6
- Issue Sort Value:
- 2013-0007-0006-0000
- Page Start:
- 1446
- Page End:
- 1460
- Publication Date:
- 2013-11
- Subjects:
- artificial pancreas -- automated insulin delivery -- automatic control -- model predictive control -- outpatient care -- periodic control
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/193229681300700605 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23686.xml