Cadaveric Biomechanical Evaluation of Capsular Constraint and Microinstability After Hip Capsulotomy and Repair. Issue 10 (22nd October 2022)
- Record Type:
- Journal Article
- Title:
- Cadaveric Biomechanical Evaluation of Capsular Constraint and Microinstability After Hip Capsulotomy and Repair. Issue 10 (22nd October 2022)
- Main Title:
- Cadaveric Biomechanical Evaluation of Capsular Constraint and Microinstability After Hip Capsulotomy and Repair
- Authors:
- Donnelly, Emma
Vakili, Samira
Getgood, Alan
Willing, Ryan
Degen, Ryan M. - Abstract:
- Background: It remains unclear if capsular management contributes to iatrogenic instability (microinstability) after hip arthroscopy. Purpose: To evaluate changes in torque, stiffness, and femoral head displacement after capsulotomy and repair in a cadaveric model. Study Design: Controlled laboratory study. Methods: A biomechanical analysis was performed using 10 cadaveric hip specimens. Each specimen was tested under the following conditions: (1) intact, (2) portals, (3) interportal capsulotomy (IPC), (4) IPC repair, (5) T-capsulotomy (T-cap), (6) partial T-cap repair, and (7) T-cap repair. Each capsular state was tested in neutral (0°) and then 30°, 60°, and 90° of flexion, with forces applied to achieve the displacement-controlled baseline limit of external rotation (ER), internal rotation (IR), abduction, and adduction. The resultant end-range torques and displacement were recorded. Results: For ER, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; capsular repairs failed to restore torque and stiffness at 0°; and IPC repair failed to restore stiffness at 30° ( P < .05 for all). For IR, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; and capsular repairs failed to restore torque or stiffness at 0°, 30°, and 60° and failed to restore stiffness at 90° ( P < .05 for all). For abduction, IPC significantly decreased torque at 60° and 90° and decreased stiffnessBackground: It remains unclear if capsular management contributes to iatrogenic instability (microinstability) after hip arthroscopy. Purpose: To evaluate changes in torque, stiffness, and femoral head displacement after capsulotomy and repair in a cadaveric model. Study Design: Controlled laboratory study. Methods: A biomechanical analysis was performed using 10 cadaveric hip specimens. Each specimen was tested under the following conditions: (1) intact, (2) portals, (3) interportal capsulotomy (IPC), (4) IPC repair, (5) T-capsulotomy (T-cap), (6) partial T-cap repair, and (7) T-cap repair. Each capsular state was tested in neutral (0°) and then 30°, 60°, and 90° of flexion, with forces applied to achieve the displacement-controlled baseline limit of external rotation (ER), internal rotation (IR), abduction, and adduction. The resultant end-range torques and displacement were recorded. Results: For ER, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; capsular repairs failed to restore torque and stiffness at 0°; and IPC repair failed to restore stiffness at 30° ( P < .05 for all). For IR, capsulotomies significantly reduced torque and stiffness at 0°, 30°, and 60° and reduced stiffness at 90°; and capsular repairs failed to restore torque or stiffness at 0°, 30°, and 60° and failed to restore stiffness at 90° ( P < .05 for all). For abduction, IPC significantly decreased torque at 60° and 90° and decreased stiffness at all positions; T-cap reduced torque and stiffness at all positions; IPC repair failed to restore stiffness at 0° and 90°; and T-cap repair failed at 0°, 60°, and 90° ( P < .05 for all). For adduction, IPC significantly reduced torque at 0° and reduced stiffness at 0° and 30°; T-cap reduced torque at 0° and 90° and reduced stiffness at all positions; IPC repair failed to restore stiffness at 0° and 90°; and T-cap repair failed at 0°, 60°, and 90° ( P < .05 for all). There were no statistically significant femoral head translations observed in any testing configurations. Conclusion: Complete capsular repair did not always restore intact kinematics, most notably at 0° and 30°. Despite this, there were no significant joint translations to corroborate concerns of microinstability. Clinical Relevance: Caution should be employed when applying rotational torques in lower levels of flexion (0° and 30°). … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 10:Issue 10(2022)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 10:Issue 10(2022)
- Issue Display:
- Volume 10, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 10
- Issue Sort Value:
- 2022-0010-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-22
- Subjects:
- hip -- biomechanical -- capsulotomy -- capsular repair
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/23259671221128348 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23731.xml