Accuracy, reproducibility, and variability of hand-held dynamometry in motor neuron disease. Issue 3 (March 1994)
- Record Type:
- Journal Article
- Title:
- Accuracy, reproducibility, and variability of hand-held dynamometry in motor neuron disease. Issue 3 (March 1994)
- Main Title:
- Accuracy, reproducibility, and variability of hand-held dynamometry in motor neuron disease.
- Authors:
- Goonetilleke, A
Modarres-Sadeghi, H
Guiloff, R J - Abstract:
- Abstract : A spring-loaded device that "breaks" at preset forces was used to assess readings obtained by hand-held dynamometry by three raters with varying experience in the method. Overall accuracy (3%), but not reproducibility or variability, was improved by greater experience. Readings obtained jointly by three raters had 53% greater variability than those obtained by a single rater. Nine muscle groups in 19 patients with motor neuron disease were assessed at 10 sessions (three replications per session) over six days by the experienced rater. Muscle force was expressed relative to that of 22 matched normal controls. The reproducibility was good with a mean % difference of 13.2 and repeatability coefficient of 2.17 kg-force for readings six days apart; the overall correlation coefficient was 0.98. The mean coefficient of variation (CV) of 10 readings was 9.9%. The poorer reproducibility and greater variability seen in clinically weaker muscles may account for differences in patients with bulbar palsy and classical amyotrophic lateral sclerosis; the degree of spasticity had no effect. The rater was estimated to contribute 37% of the total variability when testing patients. The use of a composite score by combining normalised dynamometry readings of eight limb muscles improved mean % difference to 6.7 and mean CV to 5.8%. The reproducibility and variability of hand-held dynamometry readings obtained by a single rater compare well with those of fixed devices. Readings fromAbstract : A spring-loaded device that "breaks" at preset forces was used to assess readings obtained by hand-held dynamometry by three raters with varying experience in the method. Overall accuracy (3%), but not reproducibility or variability, was improved by greater experience. Readings obtained jointly by three raters had 53% greater variability than those obtained by a single rater. Nine muscle groups in 19 patients with motor neuron disease were assessed at 10 sessions (three replications per session) over six days by the experienced rater. Muscle force was expressed relative to that of 22 matched normal controls. The reproducibility was good with a mean % difference of 13.2 and repeatability coefficient of 2.17 kg-force for readings six days apart; the overall correlation coefficient was 0.98. The mean coefficient of variation (CV) of 10 readings was 9.9%. The poorer reproducibility and greater variability seen in clinically weaker muscles may account for differences in patients with bulbar palsy and classical amyotrophic lateral sclerosis; the degree of spasticity had no effect. The rater was estimated to contribute 37% of the total variability when testing patients. The use of a composite score by combining normalised dynamometry readings of eight limb muscles improved mean % difference to 6.7 and mean CV to 5.8%. The reproducibility and variability of hand-held dynamometry readings obtained by a single rater compare well with those of fixed devices. Readings from single raters, irrespective of experience, have similar reproducibility and variability. If, however, multiple raters are used in longitudinal assessments of individual patients, as occurs in clinical trials, the variability of their combined readings should be estimated when calculating the same size required. … (more)
- Is Part Of:
- Journal of neurology, neurosurgery and psychiatry. Volume 57:Issue 3(1994)
- Journal:
- Journal of neurology, neurosurgery and psychiatry
- Issue:
- Volume 57:Issue 3(1994)
- Issue Display:
- Volume 57, Issue 3 (1994)
- Year:
- 1994
- Volume:
- 57
- Issue:
- 3
- Issue Sort Value:
- 1994-0057-0003-0000
- Page Start:
- 326
- Page End:
- 332
- Publication Date:
- 1994-03
- Subjects:
- Neurology -- Periodicals
Nervous system -- Surgery -- Periodicals
Psychiatry -- Periodicals
616.8 - Journal URLs:
- http://jnnp.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?action=archive&journal=192 ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/jnnp.57.3.326 ↗
- Languages:
- English
- ISSNs:
- 0022-3050
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23661.xml