N-terminal proatrial natriuretic peptide correlates with systolic dysfunction and left ventricular filling pattern in patients with idiopathic dilated cardiomyopathy. Issue 5 (1st November 1999)
- Record Type:
- Journal Article
- Title:
- N-terminal proatrial natriuretic peptide correlates with systolic dysfunction and left ventricular filling pattern in patients with idiopathic dilated cardiomyopathy. Issue 5 (1st November 1999)
- Main Title:
- N-terminal proatrial natriuretic peptide correlates with systolic dysfunction and left ventricular filling pattern in patients with idiopathic dilated cardiomyopathy
- Authors:
- Fruhwald, F M
Fahrleitner, A
Watzinger, N
Dobnig, H
Schumacher, M
Maier, R
Zweiker, R
Leb, G
Klein, W - Abstract:
- Abstract : OBJECTIVE: To investigate the diastolic Doppler filling pattern in patients with idiopathic dilated cardiomyopathy and its relation to N-terminal pro-atrial natriuretic peptide (NT-pro-ANP). METHODS: 32 patients (26 male, six female) with idiopathic dilated cardiomyopathy were investigated. All were in sinus rhythm. Conventional M mode echocardiography and Doppler echocardiography was done in each patient. Pulsed wave Doppler inflow signals were obtained and the following variables were measured: maximum E wave, maximum A wave, E/A ratio, E wave deceleration time, A wave deceleration time. NT-pro-ANP was measured using radioimmunoassay. RESULTS: Mean (SD) left ventricular ejection fraction was 34 (7)% and mean left ventricular end diastolic diameter on M mode echocardiography was 69 (7) mm. Left ventricular filling indices were as follows: maximum E wave velocity, 0.86 (0.22) m/s; maximum A wave velocity, 0.71 (0.24) m/s; E/A ratio, 1.41 (0.65). Mean E wave deceleration time was 140 (50) ms; mean A wave deceleration time was 100 (20) ms. In a stepwise forward regression model, NT-pro-ANP correlated significantly with left atrial diameter ( r = 0.603; p < 0.001), left ventricular ejection fraction ( r = −0.758; p < 0.001), and Doppler derived E/A ratio ( r = 0.740; p < 0.001). CONCLUSIONS: In patients with idiopathic dilated cardiomyopathy there is a relation between NT-pro-ANP and both systolic and diastolic variables. In a multivariate model NT-pro-ANPAbstract : OBJECTIVE: To investigate the diastolic Doppler filling pattern in patients with idiopathic dilated cardiomyopathy and its relation to N-terminal pro-atrial natriuretic peptide (NT-pro-ANP). METHODS: 32 patients (26 male, six female) with idiopathic dilated cardiomyopathy were investigated. All were in sinus rhythm. Conventional M mode echocardiography and Doppler echocardiography was done in each patient. Pulsed wave Doppler inflow signals were obtained and the following variables were measured: maximum E wave, maximum A wave, E/A ratio, E wave deceleration time, A wave deceleration time. NT-pro-ANP was measured using radioimmunoassay. RESULTS: Mean (SD) left ventricular ejection fraction was 34 (7)% and mean left ventricular end diastolic diameter on M mode echocardiography was 69 (7) mm. Left ventricular filling indices were as follows: maximum E wave velocity, 0.86 (0.22) m/s; maximum A wave velocity, 0.71 (0.24) m/s; E/A ratio, 1.41 (0.65). Mean E wave deceleration time was 140 (50) ms; mean A wave deceleration time was 100 (20) ms. In a stepwise forward regression model, NT-pro-ANP correlated significantly with left atrial diameter ( r = 0.603; p < 0.001), left ventricular ejection fraction ( r = −0.758; p < 0.001), and Doppler derived E/A ratio ( r = 0.740; p < 0.001). CONCLUSIONS: In patients with idiopathic dilated cardiomyopathy there is a relation between NT-pro-ANP and both systolic and diastolic variables. In a multivariate model NT-pro-ANP correlated with left atrial diameter, left ventricular ejection fraction, and Doppler derived E/A ratio on transmitral inflow. … (more)
- Is Part Of:
- Heart. Volume 82:Issue 5(1999)
- Journal:
- Heart
- Issue:
- Volume 82:Issue 5(1999)
- Issue Display:
- Volume 82, Issue 5 (1999)
- Year:
- 1999
- Volume:
- 82
- Issue:
- 5
- Issue Sort Value:
- 1999-0082-0005-0000
- Page Start:
- 630
- Page End:
- 633
- Publication Date:
- 1999-11-01
- Subjects:
- idiopathic dilated cardiomyopathy -- transmitral Doppler filling -- N-terminal pro-ANP -- atrial natriuretic factor
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.82.5.630 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23674.xml