Automatic segmentation of hippocampus in hippocampal sparing whole brain radiotherapy: A multitask edge‐aware learning. Issue 4 (9th March 2021)
- Record Type:
- Journal Article
- Title:
- Automatic segmentation of hippocampus in hippocampal sparing whole brain radiotherapy: A multitask edge‐aware learning. Issue 4 (9th March 2021)
- Main Title:
- Automatic segmentation of hippocampus in hippocampal sparing whole brain radiotherapy: A multitask edge‐aware learning
- Authors:
- Qiu, Qingtao
Yang, Ziduo
Wu, Shuyu
Qian, Dongdong
Wei, Jun
Gong, Guanzhong
Wang, Lizhen
Yin, Yong - Abstract:
- Abstract : Purpose: This study aimed to improve the accuracy of the hippocampus segmentation through multitask edge‐aware learning. Method: We developed a multitask framework for computerized hippocampus segmentation. We used three‐dimensional (3D) U‐net as our backbone model with two training objectives: (a) to minimize the difference between the targeted binary mask and the model prediction; and (b) to optimize an auxiliary edge‐prediction task which is designed to guide the model detection of the weak boundary of the hippocampus in model optimization. To balance the multiple task objectives, we proposed an improved gradient normalization by adaptively adjusting the weight of losses from different tasks. A total of 247 T1‐weighted MRIs including 131 without contrast and 116 with contrast were collected from 247 patients to train and validate the proposed method. Segmentation was quantitatively evaluated with the dice coefficient (Dice), Hausdorff distance (HD), and average Hausdorff distance (AVD). The 3D U‐net was used for baseline comparison. We used a Wilcoxon signed‐rank test to compare repeated measurements (Dice, HD, and AVD) by different segmentations. Results: Through fivefold cross‐validation, our multitask edge‐aware learning achieved Dice of 0.8483 ± 0.0036, HD of 7.5706 ± 1.2330 mm, and AVD of 0.1522 ± 0.0165 mm, respectively. Conversely, the baseline results were 0.8340 ± 0.0072, 10.4631 ± 2.3736 mm, and 0.1884 ± 0.0286 mm, respectively. With a WilcoxonAbstract : Purpose: This study aimed to improve the accuracy of the hippocampus segmentation through multitask edge‐aware learning. Method: We developed a multitask framework for computerized hippocampus segmentation. We used three‐dimensional (3D) U‐net as our backbone model with two training objectives: (a) to minimize the difference between the targeted binary mask and the model prediction; and (b) to optimize an auxiliary edge‐prediction task which is designed to guide the model detection of the weak boundary of the hippocampus in model optimization. To balance the multiple task objectives, we proposed an improved gradient normalization by adaptively adjusting the weight of losses from different tasks. A total of 247 T1‐weighted MRIs including 131 without contrast and 116 with contrast were collected from 247 patients to train and validate the proposed method. Segmentation was quantitatively evaluated with the dice coefficient (Dice), Hausdorff distance (HD), and average Hausdorff distance (AVD). The 3D U‐net was used for baseline comparison. We used a Wilcoxon signed‐rank test to compare repeated measurements (Dice, HD, and AVD) by different segmentations. Results: Through fivefold cross‐validation, our multitask edge‐aware learning achieved Dice of 0.8483 ± 0.0036, HD of 7.5706 ± 1.2330 mm, and AVD of 0.1522 ± 0.0165 mm, respectively. Conversely, the baseline results were 0.8340 ± 0.0072, 10.4631 ± 2.3736 mm, and 0.1884 ± 0.0286 mm, respectively. With a Wilcoxon signed‐rank test, we found that the differences between our method and the baseline were statistically significant ( P < 0.05 ). Conclusion: Our results demonstrated the efficiency of multitask edge‐aware learning in hippocampus segmentation for hippocampal sparing whole‐brain radiotherapy. The proposed framework may also be useful for other low‐contrast small organ segmentations on medical imaging modalities. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 4(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 4(2021)
- Issue Display:
- Volume 48, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 4
- Issue Sort Value:
- 2021-0048-0004-0000
- Page Start:
- 1771
- Page End:
- 1780
- Publication Date:
- 2021-03-09
- Subjects:
- dynamic task balancing -- hippocampal sparing whole‐brain radiotherapy -- hippocampus segmentation -- multitask learning
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14760 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23641.xml