Managing Multi-center Flow Cytometry Data for Immune Monitoring. (January 2014)
- Record Type:
- Journal Article
- Title:
- Managing Multi-center Flow Cytometry Data for Immune Monitoring. (January 2014)
- Main Title:
- Managing Multi-center Flow Cytometry Data for Immune Monitoring
- Authors:
- White, Scott
Laske, Karoline
Welters, Marij J.P.
Bidmon, Nicole
Van Der Burg, Sjoerd H.
Britten, Cedrik M.
Enzor, Jennifer
Staats, Janet
Weinhold, Kent J.
Gouttefangeas, Cέcile
Chan, Cliburn - Abstract:
- With the recent results of promising cancer vaccines and immunotherapy 1 –5, immune monitoring has become increasingly relevant for measuring treatment-induced effects on T cells, and an essential tool for shedding light on the mechanisms responsible for a successful treatment. Flow cytometry is the canonical multi-parameter assay for the fine characterization of single cells in solution, and is ubiquitously used in pre-clinical tumor immunology and in cancer immunotherapy trials. Current state-of-the-art polychromatic flow cytometry involves multi-step, multi-reagent assays followed by sample acquisition on sophisticated instruments capable of capturing up to 20 parameters per cell at a rate of tens of thousands of cells per second. Given the complexity of flow cytometry assays, reproducibility is a major concern, especially for multi-center studies. A promising approach for improving reproducibility is the use of automated analysis borrowing from statistics, machine learning and information visualization 21 –23, as these methods directly address the subjectivity, operator-dependence, labor-intensive and low fidelity of manual analysis. However, it is quite time-consuming to investigate and test new automated analysis techniques on large data sets without some centralized information management system. For large-scale automated analysis to be practical, the presence of consistent and high-quality data linked to the raw FCS files is indispensable. In particular, the use ofWith the recent results of promising cancer vaccines and immunotherapy 1 –5, immune monitoring has become increasingly relevant for measuring treatment-induced effects on T cells, and an essential tool for shedding light on the mechanisms responsible for a successful treatment. Flow cytometry is the canonical multi-parameter assay for the fine characterization of single cells in solution, and is ubiquitously used in pre-clinical tumor immunology and in cancer immunotherapy trials. Current state-of-the-art polychromatic flow cytometry involves multi-step, multi-reagent assays followed by sample acquisition on sophisticated instruments capable of capturing up to 20 parameters per cell at a rate of tens of thousands of cells per second. Given the complexity of flow cytometry assays, reproducibility is a major concern, especially for multi-center studies. A promising approach for improving reproducibility is the use of automated analysis borrowing from statistics, machine learning and information visualization 21 –23, as these methods directly address the subjectivity, operator-dependence, labor-intensive and low fidelity of manual analysis. However, it is quite time-consuming to investigate and test new automated analysis techniques on large data sets without some centralized information management system. For large-scale automated analysis to be practical, the presence of consistent and high-quality data linked to the raw FCS files is indispensable. In particular, the use of machine-readable standard vocabularies to characterize channel metadata is essential when constructing analytic pipelines to avoid errors in processing, analysis and interpretation of results. For automation, this high-quality metadata needs to be programmatically accessible, implying the need for a consistent Application Programming Interface (API). In this manuscript, we propose that upfront time spent normalizing flow cytometry data to conform to carefully designed data models enables automated analysis, potentially saving time in the long run. The ReFlow informatics framework was developed to address these data management challenges. … (more)
- Is Part Of:
- Cancer informatics. Volume 13(2014)Supplement 7
- Journal:
- Cancer informatics
- Issue:
- Volume 13(2014)Supplement 7
- Issue Display:
- Volume 13, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 13
- Issue:
- 7
- Issue Sort Value:
- 2014-0013-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-01
- Subjects:
- Flow cytometry -- data management -- metadata -- data provenance -- reproducible analysis -- laboratory informatics -- REST API -- automated analysis
Bioinformatics -- Periodicals
Biology -- Data processing -- Periodicals
Cancer -- Periodicals
Cancer -- Research -- Periodicals
Computational biology -- Periodicals
570.285 - Journal URLs:
- http://insights.sagepub.com/journal.php?journal_id=10&tab=volume ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.4137/CIN.S16346 ↗
- Languages:
- English
- ISSNs:
- 1176-9351
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23635.xml