Ultra-low-dose thoracic CT with model-based iterative reconstruction (MBIR) in cystic fibrosis patients undergoing treatment with cystic fibrosis transmembrane conductance regulators (CFTR). Issue 5 (May 2021)
- Record Type:
- Journal Article
- Title:
- Ultra-low-dose thoracic CT with model-based iterative reconstruction (MBIR) in cystic fibrosis patients undergoing treatment with cystic fibrosis transmembrane conductance regulators (CFTR). Issue 5 (May 2021)
- Main Title:
- Ultra-low-dose thoracic CT with model-based iterative reconstruction (MBIR) in cystic fibrosis patients undergoing treatment with cystic fibrosis transmembrane conductance regulators (CFTR)
- Authors:
- Moloney, F.
Kavanagh, R.G.
Ronan, N.J.
Grey, T.M.
Joyce, S.
Ryan, D.J.
Moore, N.
O'Connor, O.J.
Plant, B.J.
Maher, M.M. - Abstract:
- Abstract : AIM: To assess the utility of a volumetric low-dose computed tomography (CT) thorax (LDCTT) protocol at a dose equivalent to a posteroanterior (PA) and lateral chest radiograph for surveillance of cystic fibrosis (CF) patients. MATERIALS AND METHODS: A prospective study was undertaken of 19 adult patients with CF that proceeded to LDCTT at 12 and 24 months following initiation of ivacaftor. A previously validated seven-section, low-dose axial CT protocol was used for the 12-month study. A volumetric LDCTT protocol was developed for the 24-month study and reconstructed with hybrid iterative reconstruction (LD-ASIR) and pure iterative reconstruction (model-based IR [LD-MBIR]). Radiation dose was recorded for each scan. Image quality was assessed quantitatively and qualitatively, and disease severity was assessed using a modified Bhalla score. Statistical analysis was performed and p -values of <0.05 were considered statistically significant. RESULTS: Volumetric LD-MBIR studies were acquired at a lower radiation dose than the seven-section studies (0.08 ± 0.01 versus 0.10 ± 0.02 mSv; p= 0.02). LD-MBIR and seven-section ASIR images had significantly lower levels of image noise compared with LD-ASIR images ( p< 0.0001). Diagnostic acceptability scores and depiction of bronchovascular structures were found to be acceptable for axial and coronal LD-MBIR images. LD-MBIR images were superior to LD-ASIR images for all qualitative parameters assessed ( p< 0.0001). NoAbstract : AIM: To assess the utility of a volumetric low-dose computed tomography (CT) thorax (LDCTT) protocol at a dose equivalent to a posteroanterior (PA) and lateral chest radiograph for surveillance of cystic fibrosis (CF) patients. MATERIALS AND METHODS: A prospective study was undertaken of 19 adult patients with CF that proceeded to LDCTT at 12 and 24 months following initiation of ivacaftor. A previously validated seven-section, low-dose axial CT protocol was used for the 12-month study. A volumetric LDCTT protocol was developed for the 24-month study and reconstructed with hybrid iterative reconstruction (LD-ASIR) and pure iterative reconstruction (model-based IR [LD-MBIR]). Radiation dose was recorded for each scan. Image quality was assessed quantitatively and qualitatively, and disease severity was assessed using a modified Bhalla score. Statistical analysis was performed and p -values of <0.05 were considered statistically significant. RESULTS: Volumetric LD-MBIR studies were acquired at a lower radiation dose than the seven-section studies (0.08 ± 0.01 versus 0.10 ± 0.02 mSv; p= 0.02). LD-MBIR and seven-section ASIR images had significantly lower levels of image noise compared with LD-ASIR images ( p< 0.0001). Diagnostic acceptability scores and depiction of bronchovascular structures were found to be acceptable for axial and coronal LD-MBIR images. LD-MBIR images were superior to LD-ASIR images for all qualitative parameters assessed ( p< 0.0001). No significant change was observed in mean Bhalla score between 1-year and 2-year studies ( p= 0.84). CONCLUSIONS: The use of a volumetric LDCTT protocol (reconstructed with pure IR) enabled acquisition of diagnostic quality CT images, which were considered extremely useful for surveillance of CF patients, at a dose equivalent to a PA and lateral chest radiograph. Highlights: CF may be evaluated with CT at a radiation dose equivalent to a chest radiograph. Low dose thoracic CT may be acquired with a mean ED of 0.08 ± 0.01mSv. Compared with ASIR, MBIR images demonstrate superior objective image parameters. … (more)
- Is Part Of:
- Clinical radiology. Volume 76:Issue 5(2021)
- Journal:
- Clinical radiology
- Issue:
- Volume 76:Issue 5(2021)
- Issue Display:
- Volume 76, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 76
- Issue:
- 5
- Issue Sort Value:
- 2021-0076-0005-0000
- Page Start:
- 393.e9
- Page End:
- 393.e17
- Publication Date:
- 2021-05
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2020.12.003 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23606.xml