Multi-observer concordance and accuracy of the British Thoracic Society scale and other visual assessment qualitative criteria for solid pulmonary nodule assessment using FDG PET-CT. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- Multi-observer concordance and accuracy of the British Thoracic Society scale and other visual assessment qualitative criteria for solid pulmonary nodule assessment using FDG PET-CT. Issue 11 (November 2020)
- Main Title:
- Multi-observer concordance and accuracy of the British Thoracic Society scale and other visual assessment qualitative criteria for solid pulmonary nodule assessment using FDG PET-CT
- Authors:
- Fatania, K.
Brown, P.J.
Xie, C.
McDermott, G.
Callister, M.E.J.
Graham, R.
Subesinghe, M.
Gleeson, F.V.
Scarsbrook, A.F. - Abstract:
- Abstract : AIM: To compare the interobserver reliability and diagnostic accuracy of the British Thoracic Society (BTS) scale and other visual assessment criteria in the context of 2-[ 18 F]-fluoro-2-deoxy-d- glucose (FDG) positron-emission tomography (PET)-computed tomography (CT) evaluation of solid pulmonary nodules (SPNs). MATERIALS AND METHODS: Fifty patients who underwent FDG PET-CT for assessment of a SPN were identified. Seven reporters with varied experience at four centres graded FDG uptake visually using the British Thoracic Society (BTS) four-point scale. Five reporters also scored SPNs according to three- and five-point visual assessment scales and using semi-quantitative assessment (maximum standardised uptake value [SUVmax ]). Interobserver reliability was assessed with the intra-class correlation coefficient (ICC) and weighted Cohen's kappa (κ). Diagnostic performance was evaluated by receiver operator characteristic (ROC) analysis. RESULTS: Good interobserver reliability was demonstrated with the BTS scale (ICC=0.78, 95% confidence interval [CI]: 0.69–0.85) and five-point scale (ICC=0.78, 95 CI 0.68–0.86), whilst the three-point scale demonstrated moderate reliability (ICC=0.70, 95% CI: 0.59–0.80). Almost perfect agreement was achieved between two consultants (κ=0.85), and substantial agreement between two other consultants (κ=0.78) using the BTS scale. ROC curves for the BTS and five-point scales demonstrated equivalent accuracy (BTS area under the ROC curveAbstract : AIM: To compare the interobserver reliability and diagnostic accuracy of the British Thoracic Society (BTS) scale and other visual assessment criteria in the context of 2-[ 18 F]-fluoro-2-deoxy-d- glucose (FDG) positron-emission tomography (PET)-computed tomography (CT) evaluation of solid pulmonary nodules (SPNs). MATERIALS AND METHODS: Fifty patients who underwent FDG PET-CT for assessment of a SPN were identified. Seven reporters with varied experience at four centres graded FDG uptake visually using the British Thoracic Society (BTS) four-point scale. Five reporters also scored SPNs according to three- and five-point visual assessment scales and using semi-quantitative assessment (maximum standardised uptake value [SUVmax ]). Interobserver reliability was assessed with the intra-class correlation coefficient (ICC) and weighted Cohen's kappa (κ). Diagnostic performance was evaluated by receiver operator characteristic (ROC) analysis. RESULTS: Good interobserver reliability was demonstrated with the BTS scale (ICC=0.78, 95% confidence interval [CI]: 0.69–0.85) and five-point scale (ICC=0.78, 95 CI 0.68–0.86), whilst the three-point scale demonstrated moderate reliability (ICC=0.70, 95% CI: 0.59–0.80). Almost perfect agreement was achieved between two consultants (κ=0.85), and substantial agreement between two other consultants (κ=0.78) using the BTS scale. ROC curves for the BTS and five-point scales demonstrated equivalent accuracy (BTS area under the ROC curve [AUC]=0.768; five-point AUC=0.768). SUVmax was no more accurate compared to the BTS scale (SUVmax AUC=0.794; BTS AUC=0.768, p =0.43). CONCLUSIONS: The BTS scale can be applied reliably by reporters with varied levels of PET-CT reporting experience, across different centres and has a diagnostic performance that is not surpassed by alternative scales. Highlights: British Thoracic Society scale of FDG uptake has good inter-observer agreement. British Thoracic Society scale is as reliable as 3 and 5 point visual scales. Visual assessment showed good agreement between reporters across institutions. Semi-quantitative assessment did not improve the diagnostic accuracy. … (more)
- Is Part Of:
- Clinical radiology. Volume 75:Issue 11(2020)
- Journal:
- Clinical radiology
- Issue:
- Volume 75:Issue 11(2020)
- Issue Display:
- Volume 75, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 75
- Issue:
- 11
- Issue Sort Value:
- 2020-0075-0011-0000
- Page Start:
- 878.e21
- Page End:
- 878.e28
- Publication Date:
- 2020-11
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2020.06.028 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23614.xml