A prospective, single-arm, multicentre clinical evaluation of a new localisation technique using non-radioactive Magseeds for surgery of clinically occult breast lesions. Issue 12 (December 2019)
- Record Type:
- Journal Article
- Title:
- A prospective, single-arm, multicentre clinical evaluation of a new localisation technique using non-radioactive Magseeds for surgery of clinically occult breast lesions. Issue 12 (December 2019)
- Main Title:
- A prospective, single-arm, multicentre clinical evaluation of a new localisation technique using non-radioactive Magseeds for surgery of clinically occult breast lesions
- Authors:
- Thekkinkattil, D.
Kaushik, M.
Hoosein, M.M.
Al-Attar, M.
Pilgrim, S.
Gvaramadze, A.
Hyklova, L.
Jibril, A. - Abstract:
- Abstract : AIM: To evaluate the safety, usefulness, and outcome of Magseed localisation for surgery of non-palpable breast lesions in a non-experimental setting. MATERIALS AND METHODS: An audit was undertaken of a prospectively maintained database of patients who had undergone breast surgery under Magseed guidance in two high-volume institutions in the UK. Patients were selected for Magseed localisation depending on service convenience. Wire localisations were used in other patients in accordance with previous normal practice. One hundred and thirty-nine Magseed localisaton procedures were performed between September 2017 and March 2019. Data were collected on age, body mass index, size, bra cup size, weight of specimen, surgery, histology, re-excision rate, and time and mode of insertion of seeds. RESULTS: A total of 137 patients had Magseed localisation with a total of 139 seeds. Sixteen patients had a diagnostic procedure and 121 had therapeutic surgery. The distribution of procedures were similar between the two institutes ( n= 63 and n= 74). Mean age was 60 (range 28–81) years. The majority of seeds were placed under ultrasound guidance ( n= 112) and 25 lesions were targeted under stereo guidance. Mean size of the lesions was 15.2 (range 1–85) mm. The mean weight of the specimen was 75.5 (range 2–1, 900) g. The mean body mass index was 30.56 (range 18.1–48.3). All Magseeds and index lesions were retrieved. The re-excision rate for patients who underwent therapeuticAbstract : AIM: To evaluate the safety, usefulness, and outcome of Magseed localisation for surgery of non-palpable breast lesions in a non-experimental setting. MATERIALS AND METHODS: An audit was undertaken of a prospectively maintained database of patients who had undergone breast surgery under Magseed guidance in two high-volume institutions in the UK. Patients were selected for Magseed localisation depending on service convenience. Wire localisations were used in other patients in accordance with previous normal practice. One hundred and thirty-nine Magseed localisaton procedures were performed between September 2017 and March 2019. Data were collected on age, body mass index, size, bra cup size, weight of specimen, surgery, histology, re-excision rate, and time and mode of insertion of seeds. RESULTS: A total of 137 patients had Magseed localisation with a total of 139 seeds. Sixteen patients had a diagnostic procedure and 121 had therapeutic surgery. The distribution of procedures were similar between the two institutes ( n= 63 and n= 74). Mean age was 60 (range 28–81) years. The majority of seeds were placed under ultrasound guidance ( n= 112) and 25 lesions were targeted under stereo guidance. Mean size of the lesions was 15.2 (range 1–85) mm. The mean weight of the specimen was 75.5 (range 2–1, 900) g. The mean body mass index was 30.56 (range 18.1–48.3). All Magseeds and index lesions were retrieved. The re-excision rate for patients who underwent therapeutic surgery was 14.8% ( n= 18). CONCLUSION: The Magseed localisation technique of non-palpable breast lesions is a safe, easy procedure, and comes with the advantage of better utilisation of theatre and radiology resources. The re-excision rate in this series is lower than the national average. Highlights: Magseed guided breast surgery is safe with a short learning curve. The re excision rate is comparable to standard wire guided surgery. Help to utilise radiology and theatre resources effectively. Magseed localisation is associated with high satisfaction among radiologists, surgeons and patients. … (more)
- Is Part Of:
- Clinical radiology. Volume 74:Issue 12(2019)
- Journal:
- Clinical radiology
- Issue:
- Volume 74:Issue 12(2019)
- Issue Display:
- Volume 74, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 74
- Issue:
- 12
- Issue Sort Value:
- 2019-0074-0012-0000
- Page Start:
- 974.e7
- Page End:
- 974.e11
- Publication Date:
- 2019-12
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2019.08.018 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23623.xml