Freezing temperature controlled deep eutectic solvent dispersive liquid–liquid microextraction based on solidification of floating organic droplets for rapid determination of benzoylureas residual in water samples with assistance of metallic salt. Issue 89 (15th December 2017)
- Record Type:
- Journal Article
- Title:
- Freezing temperature controlled deep eutectic solvent dispersive liquid–liquid microextraction based on solidification of floating organic droplets for rapid determination of benzoylureas residual in water samples with assistance of metallic salt. Issue 89 (15th December 2017)
- Main Title:
- Freezing temperature controlled deep eutectic solvent dispersive liquid–liquid microextraction based on solidification of floating organic droplets for rapid determination of benzoylureas residual in water samples with assistance of metallic salt
- Authors:
- Yang, Miyi
Hong, Kun
Li, Xiaoqiang
Ge, Fangji
Tang, Yuqing - Abstract:
- Abstract : A hydrophobic deep eutectic solvent worked as an extractant to extract benzoylureas with assistance of FeCl3 contained dispersive-demulsified solvent. Abstract : An efficient and novel salt-assisted deep eutectic solvent (DES) dispersive liquid–liquid microextraction based on solidification of floating organic droplets combined with high performance liquid chromatography was developed for extraction and determination of four benzoylureas (BUs) in water samples. In this method, a hydrophobic deep eutectic solvent (DES) used as extractant was dissolved in a dispersive-demulsified solvent containing FeCl3 . The influence of main factors on the efficiency of this procedure was investigated by one-factor experimental design and central composite design (CCD) successively. Under optimal conditions, the proposed method manifest good recoveries in the range of 82.36–93.82% and high precision (relative standard deviations below 5%). The enrichment factors for the analytes changed from 91 to 97. The limits of detection varied from 0.11 to 0.35 μg L −1 with the linear coefficients greater than 0.999. The method is successfully applied to determine the BUs in different water samples, which proved the potential use of this method in real samples.
- Is Part Of:
- RSC advances. Volume 7:Issue 89(2017)
- Journal:
- RSC advances
- Issue:
- Volume 7:Issue 89(2017)
- Issue Display:
- Volume 7, Issue 89 (2017)
- Year:
- 2017
- Volume:
- 7
- Issue:
- 89
- Issue Sort Value:
- 2017-0007-0089-0000
- Page Start:
- 56528
- Page End:
- 56536
- Publication Date:
- 2017-12-15
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ra11030h ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23616.xml