Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Issue 3 (1st March 2000)
- Record Type:
- Journal Article
- Title:
- Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Issue 3 (1st March 2000)
- Main Title:
- Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
- Authors:
- Whelan, D M
van der Giessen, W J
Krabbendam, S C
van Vliet, E A
Verdouw, P D
Serruys, P W
van Beusekom, H M M - Abstract:
- Abstract : OBJECTIVE: To improve the biocompatibility of stents using a phosphorylcholine coated stent as a form of biomimicry. INTERVENTIONS: Implantation of phosphorylcholine coated (n = 20) and non-coated (n = 21) stents was performed in the coronary arteries of 25 pigs. The animals were killed after five days (n = 6), four weeks (n = 7), and 12 weeks (n = 8), and the vessels harvested for histology, scanning electron microscopy, and morphometry. MAIN OUTCOME MEASURES: Stent performance was assessed by studying early endothelialisation, neointima formation, and vessel wall reaction to the synthetic coating. RESULTS: Stent thrombosis did not occur in either group. Morphometry showed no significant differences between the two study groups at any time point. At five days both the coated and non-coated stents were equally well endothelialised (91% v 92%, respectively). At four and 12 weeks there was no difference in intimal thickness between the coated and non-coated stents. Up to 12 weeks postimplant the phosphorylcholine coating was still discernible in the stent strut voids, and did not appear to elicit an adverse inflammatory response. CONCLUSION: In this animal model the phosphorylcholine coating showed excellent blood and tissue compatibility, unlike a number of other polymers tested in a similar setting. Given that the coating was present up to 12 weeks postimplant with no adverse tissue reaction, it may be a potential candidate polymer for local drug delivery.
- Is Part Of:
- Heart. Volume 83:Issue 3(2000)
- Journal:
- Heart
- Issue:
- Volume 83:Issue 3(2000)
- Issue Display:
- Volume 83, Issue 3 (2000)
- Year:
- 2000
- Volume:
- 83
- Issue:
- 3
- Issue Sort Value:
- 2000-0083-0003-0000
- Page Start:
- 338
- Page End:
- 345
- Publication Date:
- 2000-03-01
- Subjects:
- phosphorylcholine -- stents -- coatings -- biocompatible materials
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heart.83.3.338 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23550.xml