Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach. (September 2022)
- Record Type:
- Journal Article
- Title:
- Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach. (September 2022)
- Main Title:
- Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach
- Authors:
- Baghani, Hamid Reza
Gheibi, Azar
Mowlavi, Ali Asghar - Abstract:
- Highlights: Inter-seed effect (ISE) was evaluated for some commercial I-125 brachytherapy seeds. 6711, ProstaSeed, STM 1251, 3500, and IAI-125A seed models were considered. Minimum and maximum ISE were respectively found for prostaseed and 3500 seeds. ISE can affect the dose distribution around multiseed brachytherapy implants. Abstract: Background and Objective: One of the principal deficits of TG-43(U1) dosimetry protocol is ignoring the attenuation effect of each seed during the multiseed brachytherapy implants. To take into account this shadowing effect, a parameter known as the inter-seed effect ( ISE ) has been introduced. Current study aims to evaluate and compare the ISE for some I-125 brachytherapy seeds through a Monte Carlo (MC) simulation approach. Methods: Five different models of I-125 seeds including 6711, ProstaSeed, STM 1251, 3500, and IAI-125A were simulated by MCNPX MC Code. Validity of simulated seed models was confirmed through comparing the corresponding dosimetric parameters such as radial dose function and anisotropy function with those reported by relevant literature. Then, the ISE for each seed at different distances was determined in three seeds implant configuration. Additionally, the relevant attenuation factors ( AF ) were also determined for each brachytherapy source. Results: The obtained results demonstrated that minimum inter-seed attenuation belongs to the ProstaSeed. In return, the maximum inter-seed attenuation was found for 3500Highlights: Inter-seed effect (ISE) was evaluated for some commercial I-125 brachytherapy seeds. 6711, ProstaSeed, STM 1251, 3500, and IAI-125A seed models were considered. Minimum and maximum ISE were respectively found for prostaseed and 3500 seeds. ISE can affect the dose distribution around multiseed brachytherapy implants. Abstract: Background and Objective: One of the principal deficits of TG-43(U1) dosimetry protocol is ignoring the attenuation effect of each seed during the multiseed brachytherapy implants. To take into account this shadowing effect, a parameter known as the inter-seed effect ( ISE ) has been introduced. Current study aims to evaluate and compare the ISE for some I-125 brachytherapy seeds through a Monte Carlo (MC) simulation approach. Methods: Five different models of I-125 seeds including 6711, ProstaSeed, STM 1251, 3500, and IAI-125A were simulated by MCNPX MC Code. Validity of simulated seed models was confirmed through comparing the corresponding dosimetric parameters such as radial dose function and anisotropy function with those reported by relevant literature. Then, the ISE for each seed at different distances was determined in three seeds implant configuration. Additionally, the relevant attenuation factors ( AF ) were also determined for each brachytherapy source. Results: The obtained results demonstrated that minimum inter-seed attenuation belongs to the ProstaSeed. In return, the maximum inter-seed attenuation was found for 3500 brachytherapy seed. The mean attenuation factor for 6711, ProstaSeed, STM 1251, 3500, and IAI-125A seed models was equal to 0.764, 0.829, 0.785, 0.594, and 0.772, respectively. Conclusions: It can be concluded that the considered I-125 brachytherapy seeds show different inter-seed effects and mean AF values for the same multiseed implant arrangement. This finding can be attributed to discrepancies in internal seed design and configuration. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 224(2022)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 224(2022)
- Issue Display:
- Volume 224, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 224
- Issue:
- 2022
- Issue Sort Value:
- 2022-0224-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- Brachytherapy -- Iodine-125 brachytherapy seeds -- Inter-seed effect -- Dose calculations -- Monte Carlo simulation
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2022.107000 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23561.xml