Evaluation of Relative Isotopic Abundance Measurements in a Quadrupole Time-of-Flight Mass Spectrometer for Elemental Composition Determination of Natural Products in Traditional Chinese Medicine. Issue 2 (April 2013)
- Record Type:
- Journal Article
- Title:
- Evaluation of Relative Isotopic Abundance Measurements in a Quadrupole Time-of-Flight Mass Spectrometer for Elemental Composition Determination of Natural Products in Traditional Chinese Medicine. Issue 2 (April 2013)
- Main Title:
- Evaluation of Relative Isotopic Abundance Measurements in a Quadrupole Time-of-Flight Mass Spectrometer for Elemental Composition Determination of Natural Products in Traditional Chinese Medicine
- Authors:
- Wu, Zhi-Jun
Huo, Jia-Li
Chen, Jian-Zhong
Li, Na
Fang, Dong-Mei
Chen, Xiao-Zhen
Zhang, Guo-Lin
Wang, Jian-Hua
Xu, Xiao-Ying - Abstract:
- The relative isotopic abundance (RIA) measurement errors of a quadrupole time-of-flight (Q-ToF) instrument incorporating analog-to-digital converter detectors were systemically evaluated by stochastically collecting about 200 data in positive ion mass spectrometry (MS) mode. Errors varied with peak intensities at definite spectral acquisition rates but were very close, even if peak intensities changed sharply at different spectral acquisition rates with the same concentration. Intensity thresholds were systematically defined at 1 Hz of spectral acquisition rates. RIA measurement errors were also evaluated using peak area. It seemed that peak area was better adapted for the high-intensity ions while peak intensity was suited for very low-intensity ions. Several known compounds were selected for RIA measurements for product ions in tandem mass spectropmetry (MS/MS) mode. An extract of a representative traditional Chinese medicinal, Paederia scandens was analyzed with high-performance liquid chromatography-electrospray ionization-QToF-MS/MS. The unique elemental compositions of some compounds could not be identified even with exact masses and MS/MS spectra of measured and reference compounds. RIA errors, especially of (M + 2)M −1, provided vital information for determining the elemental composition.
- Is Part Of:
- European journal of mass spectrometry. Volume 19:Issue 2(2013)
- Journal:
- European journal of mass spectrometry
- Issue:
- Volume 19:Issue 2(2013)
- Issue Display:
- Volume 19, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2013-0019-0002-0000
- Page Start:
- 91
- Page End:
- 102
- Publication Date:
- 2013-04
- Subjects:
- relative isotopic abundance -- evaluation -- Q-ToF -- elemental composition -- Paederia scandens -- traditional Chinese medicine
Mass spectrometry -- Periodicals
Mass Spectrometry
Mass spectrometry
Periodicals
Periodicals
543.6505 - Journal URLs:
- http://www.impub.co.uk/ems.html ↗
http://journals.sagepub.com/toc/EMS/current ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1255/ejms.1219 ↗
- Languages:
- English
- ISSNs:
- 1469-0667
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23542.xml