In Vitro Performance Investigation of SynCardia™ Freedom® Driver via Patient Simulator Mock Loop. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- In Vitro Performance Investigation of SynCardia™ Freedom® Driver via Patient Simulator Mock Loop. Issue 10 (October 2016)
- Main Title:
- In Vitro Performance Investigation of SynCardia™ Freedom® Driver via Patient Simulator Mock Loop
- Authors:
- Toninato, Riccardo
Scuri, Silvia
Tarzia, Vincenzo
Gerosa, Gino
Susin, Francesca M. - Abstract:
- Purpose: The gold standard therapy for patients with advanced heart failure is heart transplant. The gap between donors and patients in waiting lists promoted the development of circulatory support devices, such as the total artificial heart (TAH). Focusing on in vitro tests performed with CardioWest ™ TAH (CW) driven by the SynCardia Freedom ® portable driver (FD) the present study goals are: i) prove the reliability of a hydraulic circuit used as patient simulator to replicate a quasi-physiological scenario for various hydrodynamic conditions, ii) investigate the hydrodynamic performance of the CW FD, iii) help clinicians in possible interpretation of clinical cases outcomes. Methods: In vitro tests were performed using a mechanic-hydraulic patient simulator. Cardiac output (CO), CW ventricles filling, atrial, ventricles, aortic and pulmonary artery pressures were measured for different values of vascular resistance in both systemic (SVR) and pulmonary (PVR) physiological range. Results: After increasing the PVR, the left atrial pressure decreased according to the expected physiological trend, while aortic pressure remained almost stable, proving the ability of the simulator to mimic a physiological scenario. Unexpectedly, the mean pulmonary artery pressure (P) was found to increase above 30 mmHg in the range of physiological PVR (2.6 WU) and for constant CO. Conclusions: The increase in PPA is probably associated with the pre-set driving setup of the FD. The findingPurpose: The gold standard therapy for patients with advanced heart failure is heart transplant. The gap between donors and patients in waiting lists promoted the development of circulatory support devices, such as the total artificial heart (TAH). Focusing on in vitro tests performed with CardioWest ™ TAH (CW) driven by the SynCardia Freedom ® portable driver (FD) the present study goals are: i) prove the reliability of a hydraulic circuit used as patient simulator to replicate a quasi-physiological scenario for various hydrodynamic conditions, ii) investigate the hydrodynamic performance of the CW FD, iii) help clinicians in possible interpretation of clinical cases outcomes. Methods: In vitro tests were performed using a mechanic-hydraulic patient simulator. Cardiac output (CO), CW ventricles filling, atrial, ventricles, aortic and pulmonary artery pressures were measured for different values of vascular resistance in both systemic (SVR) and pulmonary (PVR) physiological range. Results: After increasing the PVR, the left atrial pressure decreased according to the expected physiological trend, while aortic pressure remained almost stable, proving the ability of the simulator to mimic a physiological scenario. Unexpectedly, the mean pulmonary artery pressure (P) was found to increase above 30 mmHg in the range of physiological PVR (2.6 WU) and for constant CO. Conclusions: The increase in PPA is probably associated with the pre-set driving setup of the FD. The finding suggests a possible explanation of the clinical course of a patient who experienced complications soon after being supported by the FD, with the occurrence of dyspnea and pulmonary edema despite a high cardiac index. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 39:Issue 10(2016:Oct.)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 39:Issue 10(2016:Oct.)
- Issue Display:
- Volume 39, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 39
- Issue:
- 10
- Issue Sort Value:
- 2016-0039-0010-0000
- Page Start:
- 502
- Page End:
- 508
- Publication Date:
- 2016-10
- Subjects:
- Freedom drive unit -- Mock loop -- Patient simulator -- Pulmonary hypertension -- Total artificial heart
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.5301/ijao.5000524 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23530.xml