The effect on upper extremity functions of cardiac electronic device placement on the dominant hand side. Issue 2 (21st January 2019)
- Record Type:
- Journal Article
- Title:
- The effect on upper extremity functions of cardiac electronic device placement on the dominant hand side. Issue 2 (21st January 2019)
- Main Title:
- The effect on upper extremity functions of cardiac electronic device placement on the dominant hand side
- Authors:
- Şimşek, Ersin Çağrı
Uslu Güvendi, Ece
Şimşek, Aylin
Kocabaş, Uğur
Varış, Eser
Gürbüz, Doğaç Çağlar
Aşkin, Ayhan - Abstract:
- Abstract: Background: Although cardiac implantable electronic device (CIED) implantation is considered to be minor surgery, almost 60% of the patients suffer from shoulder‐related problems a short time after the procedure. The purpose of this study was to determine the possible effects of the preference of the dominant side for CIED implantation on the ipsilateral superior extremity functions. Methods: The study included a total of 107 patients who had been living with a CIED for >6 months. Patients were separated into two groups according to the dominant hand and side of the CIED. The ipsilateral dominant‐hand group comprised those with a CIED on the same side as the dominant hand and the contralateral dominant‐hand group included patients with the CIED placed on the contralateral side to the dominant hand. Visual analogue scale (VAS) pain score, quick disability of the arm shoulder and hand questionnaire (QuickDASH) and maximum isometric grip strength tests were used to evaluate the upper extremity disabilities. Results: No significant difference was determined between the groups in respect of VAS pain scores ( P = 0.10), QuickDASH scores ( P = 0.21), and limitations of the shoulder joint range of motion ( P = 0.192). The maximum isometric grip strength was significantly different in the right hands between two groups (34 [16‐95]‐40 [24‐85]) ( P = 0.02). Conclusion: The present study shows that the joint range of motion limitation, pain, and disability of the upperAbstract: Background: Although cardiac implantable electronic device (CIED) implantation is considered to be minor surgery, almost 60% of the patients suffer from shoulder‐related problems a short time after the procedure. The purpose of this study was to determine the possible effects of the preference of the dominant side for CIED implantation on the ipsilateral superior extremity functions. Methods: The study included a total of 107 patients who had been living with a CIED for >6 months. Patients were separated into two groups according to the dominant hand and side of the CIED. The ipsilateral dominant‐hand group comprised those with a CIED on the same side as the dominant hand and the contralateral dominant‐hand group included patients with the CIED placed on the contralateral side to the dominant hand. Visual analogue scale (VAS) pain score, quick disability of the arm shoulder and hand questionnaire (QuickDASH) and maximum isometric grip strength tests were used to evaluate the upper extremity disabilities. Results: No significant difference was determined between the groups in respect of VAS pain scores ( P = 0.10), QuickDASH scores ( P = 0.21), and limitations of the shoulder joint range of motion ( P = 0.192). The maximum isometric grip strength was significantly different in the right hands between two groups (34 [16‐95]‐40 [24‐85]) ( P = 0.02). Conclusion: The present study shows that the joint range of motion limitation, pain, and disability of the upper extremity were no different in the affected arm compared to the healthy contralateral side with respect to the placement of the CIED on the dominant or non‐dominant side. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 35:Issue 2(2019)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 35:Issue 2(2019)
- Issue Display:
- Volume 35, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 2
- Issue Sort Value:
- 2019-0035-0002-0000
- Page Start:
- 279
- Page End:
- 286
- Publication Date:
- 2019-01-21
- Subjects:
- arrhythmia -- cardiac implantable electronic device -- dominant hand side -- shoulder impairment -- upper extremity disabilities
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12156 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23515.xml