A multi-layer strip ionization chamber (MLSIC) device for proton pencil beam scan quality assurance. (7th September 2022)
- Record Type:
- Journal Article
- Title:
- A multi-layer strip ionization chamber (MLSIC) device for proton pencil beam scan quality assurance. (7th September 2022)
- Main Title:
- A multi-layer strip ionization chamber (MLSIC) device for proton pencil beam scan quality assurance
- Authors:
- Zhou, Shuang
Rao, Wei
Chen, Qinghao
Tan, Yuewen
Smith, Winter
Sun, Baozhou
Zhou, Jun
Chang, Chih-Wei
Lin, Liyong
Darafsheh, Arash
Zhao, Tianyu
Zhang, Tiezhi - Abstract:
- Abstract: Objective . Proton pencil beam scanning (PBS) treatment fields needs to be verified before treatment deliveries to ensure patient safety. In current practice, treatment beam quality assurance (QA) is measured at a few selected depths using film or a 2D detector array, which is insensitive and time-consuming. A QA device that can measure all key dosimetric characteristics of treatment beams spot-by-spot within a single beam delivery is highly desired. Approach . We developed a multi-layer strip ionization chamber (MLSIC) prototype device that comprises of two layers of strip ionization chambers (IC) plates for spot position measurement and 64 layers of plate IC for beam energy measurement. The 768-channel strip ion chamber signals are integrated and sampled at a speed of 3.125 kHz. It has a 25.6 cm × 25.6 cm maximum measurement field size and 2 mm spatial resolution for spot position measurement. The depth resolution and maximum depth were 2.91 mm and 18.6 cm for 1.6 mm thick IC plate, respectively. The relative weight of each spot was determined from total charge by all IC detector channels. Main results . The MLSIC is able to measure ionization currents spot-by-spot. The depth dose measurement has a good agreement with the ground truth measured using a water tank and commercial one-dimensional (1D) multi-layer plate chamber. It can verify the spot position, energy, and relative weight of clinical PBS beams and compared with the treatment plans. Significance . TheAbstract: Objective . Proton pencil beam scanning (PBS) treatment fields needs to be verified before treatment deliveries to ensure patient safety. In current practice, treatment beam quality assurance (QA) is measured at a few selected depths using film or a 2D detector array, which is insensitive and time-consuming. A QA device that can measure all key dosimetric characteristics of treatment beams spot-by-spot within a single beam delivery is highly desired. Approach . We developed a multi-layer strip ionization chamber (MLSIC) prototype device that comprises of two layers of strip ionization chambers (IC) plates for spot position measurement and 64 layers of plate IC for beam energy measurement. The 768-channel strip ion chamber signals are integrated and sampled at a speed of 3.125 kHz. It has a 25.6 cm × 25.6 cm maximum measurement field size and 2 mm spatial resolution for spot position measurement. The depth resolution and maximum depth were 2.91 mm and 18.6 cm for 1.6 mm thick IC plate, respectively. The relative weight of each spot was determined from total charge by all IC detector channels. Main results . The MLSIC is able to measure ionization currents spot-by-spot. The depth dose measurement has a good agreement with the ground truth measured using a water tank and commercial one-dimensional (1D) multi-layer plate chamber. It can verify the spot position, energy, and relative weight of clinical PBS beams and compared with the treatment plans. Significance . The MLSIC is a highly efficient QA device that can measure the key dosimetric characteristics of proton treatment beams spot-by-spot with a single beam delivery. It may improve the quality and efficiency of clinical proton treatments. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 67:Number 17(2022)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 67:Number 17(2022)
- Issue Display:
- Volume 67, Issue 17 (2022)
- Year:
- 2022
- Volume:
- 67
- Issue:
- 17
- Issue Sort Value:
- 2022-0067-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09-07
- Subjects:
- proton therapy -- quality assurance -- multilayer ionization chamber -- intensity modulated proton therapy
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ac8593 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23492.xml