Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients. (18th October 2015)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients. (18th October 2015)
- Main Title:
- Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients
- Authors:
- Muñoz-Negrete, Francisco J.
Contreras, Inés
Oblanca, Noelia
Pinazo-Durán, M. Dolores
Rebolleda, Gema - Other Names:
- Nakazawa Mitsuru Academic Editor.
- Abstract:
- Abstract : Purpose. To determine the diagnostic accuracy for glaucoma of a set of criteria with nonmydriatic monoscopic fundus photography (NMFP) in diabetics. Methods. Diabetics recruited from a screening program for diabetic retinopathy and diabetic glaucoma patients recruited from our glaucoma unit were included. Any patient with evidence of diabetic retinopathy was excluded. Diabetic patients had to have no visual field defects to be included as controls. Glaucoma patients had to have a glaucomatous field defect in at least one eye to be included. One NMFP was taken per eye for all subjects. These photographs were evaluated by two masked glaucoma specialists for the presence of the following: bilateral cup to disc (C/D) ratio ≥0.6, notching or thinning of the neuroretinal rim, disc hemorrhages, and asymmetry in the C/D ratio between both eyes ≥0.2. This evaluation led to a dichotomous classification: if any of the above criteria was present, the patient was classified as glaucoma. If none were present, the patient was classified as normal. Results. 72 control subjects and 72 glaucoma patients were included. Evaluation of NMFP had a sensitivity of 79.17% and a specificity of 80.56% for specialist 1 and a sensitivity of 72.22% and a specificity of 88.88% for specialist 2 for the detection of glaucoma. The overall accuracy was 79.83% and 80.55%, respectively. Discussion. NMFP evaluation by a glaucoma specialist may be useful for the detection of glaucoma in diabetics.
- Is Part Of:
- BioMed research international. Volume 2015(2015)
- Journal:
- BioMed research international
- Issue:
- Volume 2015(2015)
- Issue Display:
- Volume 2015, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 2015
- Issue:
- 2015
- Issue Sort Value:
- 2015-2015-2015-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10-18
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2015/892174 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23497.xml