Comparative Analysis of Methods to Induce Myocardial Infarction in a Closed-Chest Rabbit Model. (4th October 2015)
- Record Type:
- Journal Article
- Title:
- Comparative Analysis of Methods to Induce Myocardial Infarction in a Closed-Chest Rabbit Model. (4th October 2015)
- Main Title:
- Comparative Analysis of Methods to Induce Myocardial Infarction in a Closed-Chest Rabbit Model
- Authors:
- Isorni, Marc-Antoine
Casanova, Amaury
Piquet, Julie
Bellamy, Valérie
Pignon, Charly
Puymirat, Etienne
Menasche, Philippe - Other Names:
- Schmack Bastian Academic Editor.
- Abstract:
- Abstract : Objective. To develop a rabbit model of closed-chest catheter-induced myocardial infarction. Background. Limitations of rodent and large animal models justify the search for clinically relevant alternatives. Methods. Microcatheterization of the heart was performed in 47 anesthetized 3-4 kg New Zealand rabbits to test five techniques of myocardial ischemia: free coils (n = 4 ), interlocking coils (n = 4 ), thrombogenic gelatin sponge (n = 4 ), balloon occlusion (n = 4 ), and alcohol injection (n = 8 ). In order to limit ventricular fibrillation, an antiarrhythmic protocol was implemented, with beta-blockers/amiodarone before and xylocaine infusion during the procedure. Clinical, angiographic, and echographic data were gathered. End points included demonstration of vessel occlusion (TIMI flow grades 0 and 1 on the angiogram), impairment of left ventricular function at 2 weeks after procedure (by echocardiography), and pathologically confirmed myocardial infarction. Results. The best arterial access was determined to be through the right carotid artery. The internal mammary guiding catheter 4-Fr was selected as the optimal device for selective intracoronary injection. Free coils deployed prematurely and tended to prolapse into the aorta. Interlocking coils did not deploy completely and failed to provide reliable results. Gelatin sponge was difficult to handle, adhered to the catheter, and could not be clearly visualized by fluoroscopy. Balloon occlusion yieldedAbstract : Objective. To develop a rabbit model of closed-chest catheter-induced myocardial infarction. Background. Limitations of rodent and large animal models justify the search for clinically relevant alternatives. Methods. Microcatheterization of the heart was performed in 47 anesthetized 3-4 kg New Zealand rabbits to test five techniques of myocardial ischemia: free coils (n = 4 ), interlocking coils (n = 4 ), thrombogenic gelatin sponge (n = 4 ), balloon occlusion (n = 4 ), and alcohol injection (n = 8 ). In order to limit ventricular fibrillation, an antiarrhythmic protocol was implemented, with beta-blockers/amiodarone before and xylocaine infusion during the procedure. Clinical, angiographic, and echographic data were gathered. End points included demonstration of vessel occlusion (TIMI flow grades 0 and 1 on the angiogram), impairment of left ventricular function at 2 weeks after procedure (by echocardiography), and pathologically confirmed myocardial infarction. Results. The best arterial access was determined to be through the right carotid artery. The internal mammary guiding catheter 4-Fr was selected as the optimal device for selective intracoronary injection. Free coils deployed prematurely and tended to prolapse into the aorta. Interlocking coils did not deploy completely and failed to provide reliable results. Gelatin sponge was difficult to handle, adhered to the catheter, and could not be clearly visualized by fluoroscopy. Balloon occlusion yielded inconsistent results. Alcohol injection was the most efficient and reproducible method for inducing myocardial infarction (4 out of 6 animals), the extent of which could be fine-tuned by using a coaxial balloon catheter as a microcatheter (0.52 mm) to achieve a superselective injection of 0.2 mL of alcohol. This approach resulted in a 20% decrease in LVEF and infarcted myocardium was confirmed histologically. Conclusions. By following a stepwise approach, a minimally invasive, effective, and reproducible rabbit model of catheter-induced myocardial infarction has been developed which addresses the limitations of rodent experiments while avoiding the logistical and cost issues associated with large animal models. … (more)
- Is Part Of:
- BioMed research international. Volume 2015(2015)
- Journal:
- BioMed research international
- Issue:
- Volume 2015(2015)
- Issue Display:
- Volume 2015, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 2015
- Issue:
- 2015
- Issue Sort Value:
- 2015-2015-2015-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-10-04
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2015/893051 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23496.xml