Establishment of rapid, sensitive, and quantitative liquid chromatography‐electrospray ionization‐tandem mass spectrometry method coupled with liquid–liquid extraction for measurement of urinary bisphenol A, 4‐t‐octylphenol, and 4‐nonylphenol. (23rd April 2021)
- Record Type:
- Journal Article
- Title:
- Establishment of rapid, sensitive, and quantitative liquid chromatography‐electrospray ionization‐tandem mass spectrometry method coupled with liquid–liquid extraction for measurement of urinary bisphenol A, 4‐t‐octylphenol, and 4‐nonylphenol. (23rd April 2021)
- Main Title:
- Establishment of rapid, sensitive, and quantitative liquid chromatography‐electrospray ionization‐tandem mass spectrometry method coupled with liquid–liquid extraction for measurement of urinary bisphenol A, 4‐t‐octylphenol, and 4‐nonylphenol
- Authors:
- Battal, Dilek
Sukuroglu, Ayca Aktas
Kocadal, Kumsal
Cok, Ismet
Unlusayin, Irfan - Abstract:
- Abstract : Rationale: Bisphenol A (BPA), 4‐ t ‐octylphenol (4‐ t ‐OP), and 4‐nonylphenol (4‐NP) are ubiquitous manufactured chemicals classified as endocrine disruptors. Now these substances are prevalent and found in a wide range of biological and environmental matrices globally. Acting as xenoestrogens, their target is to bind estrogen receptors and compete against natural hormones. Thus, there is an increasing concern on their negative health consequences. Methods: A rapid, sensitive, and robust method was established, validated, and used for the trace analysis of BPA, 4‐ t ‐OP, and 4‐NP in human urine using liquid chromatography‐electrospray ionization‐tandem mass spectrometry. Results: The linear ranges for BPA, 4‐ t ‐OP, and 4‐NP were 5.0–500 ng/mL. The correlation coefficient was higher than 0.996. The limit of detection and limit of quantitation for the compounds were 0.001, 0.007, and 0.005 ng/mL and 0.005, 0.023, and 0.180 ng/mL, respectively. The recoveries were as follows: 99.539%–108.557%, 97.780%–110.768%, and 99.694%–106.908% for BPA, 4‐NP, and 4‐ t ‐OP respectively, with relative standard deviation <8.26%. Conclusions: The established method was also applied effectively for the determination of BPA, 4‐ t ‐OP, and 4‐NP levels in 15 human urine samples. This method was specifically developed for easy and precise analysis of BPA, 4‐ t ‐OP, and 4‐NP in human urine. The method developed has been shown to be accurate, precise, and sensitive.
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 35:Number 12(2021)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 35:Number 12(2021)
- Issue Display:
- Volume 35, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 35
- Issue:
- 12
- Issue Sort Value:
- 2021-0035-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-04-23
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.9084 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23486.xml