Pipeline for Distal Cerebral Circulation Aneurysms. Issue 3 (20th March 2019)
- Record Type:
- Journal Article
- Title:
- Pipeline for Distal Cerebral Circulation Aneurysms. Issue 3 (20th March 2019)
- Main Title:
- Pipeline for Distal Cerebral Circulation Aneurysms
- Authors:
- Atallah, Elias
Saad, Hassan
Mouchtouris, Nikolaos
Bekelis, Kimon
Walker, Jackson
Chalouhi, Nohra
Tjoumakaris, Stavropoula
Smith, Michelle
Rosenwasser, Robert H
Zarzour, Hekmat
Herial, Nabeel
Feghali, James
Gooch, Michael Reid
Missios, Symeon
Sweid, Ahmad
Jabbour, Pascal - Abstract:
- Abstract: BACKGROUND: Pipeline embolization device (PED; Medtronic, Dublin, Ireland) utilization is not limited to the treatment of giant wide-necked aneurysms. It has been expanded to handle small blisters, fusiforms, and dissecting intracranial aneurysms. OBJECTIVE: To report the use of the PED in various off-label distal cerebral circulation (DCC) arteries with a follow-up to assess clinical outcomes. METHODS: Between 2011 and 2016, of 437 consecutive patients, 23 patients with aneurysms located in DCCs were treated with PED. Data on patient presentation, aneurysm characteristics, procedural outcomes, postoperative course, and aneurysm occlusion were gathered. To control confounding, we used multivariable logistic regression and propensity score conditioning. RESULTS: A total of 437 patients (mean age 52.12 years; 62 women [14.2%]) underwent treatment with PED in our institution. Twenty-three of 437 (5.2%) received a pipeline in a distal artery: 11/23 middle cerebral artery, 6/23 posterior cerebral artery, 3/23 anterior cerebral artery (A1/A2, pericallosal artery), and 3/23 posterior inferior cerebellar artery. Twenty percent of the aneurysms were treated in the past, 10% had previously ruptured, and 5.9% ruptured at presentation to our hospital. The mean aneurysm size was 9.0 ± 6 mm. The mean follow-up was 12 mo (SD = 12.5). In multivariable logistic regression, no associations were found between PED deployment in DCCs and aneurysm occlusion or thromboembolicAbstract: BACKGROUND: Pipeline embolization device (PED; Medtronic, Dublin, Ireland) utilization is not limited to the treatment of giant wide-necked aneurysms. It has been expanded to handle small blisters, fusiforms, and dissecting intracranial aneurysms. OBJECTIVE: To report the use of the PED in various off-label distal cerebral circulation (DCC) arteries with a follow-up to assess clinical outcomes. METHODS: Between 2011 and 2016, of 437 consecutive patients, 23 patients with aneurysms located in DCCs were treated with PED. Data on patient presentation, aneurysm characteristics, procedural outcomes, postoperative course, and aneurysm occlusion were gathered. To control confounding, we used multivariable logistic regression and propensity score conditioning. RESULTS: A total of 437 patients (mean age 52.12 years; 62 women [14.2%]) underwent treatment with PED in our institution. Twenty-three of 437 (5.2%) received a pipeline in a distal artery: 11/23 middle cerebral artery, 6/23 posterior cerebral artery, 3/23 anterior cerebral artery (A1/A2, pericallosal artery), and 3/23 posterior inferior cerebellar artery. Twenty percent of the aneurysms were treated in the past, 10% had previously ruptured, and 5.9% ruptured at presentation to our hospital. The mean aneurysm size was 9.0 ± 6 mm. The mean follow-up was 12 mo (SD = 12.5). In multivariable logistic regression, no associations were found between PED deployment in DCCs and aneurysm occlusion or thromboembolic complications. PED use in DCC was associated with a good clinical outcome. Twenty-two people of 23 (95%) had a good clinical outcome in the latest follow-up. CONCLUSION: Treatment of DCC aneurysms with PED is technically challenging mainly because of the small caliber and tortuosity of the parent arteries. The results of this study further support the safety of flow diverters in the treatment of various distal aneurysms. Graphical Abstract: … (more)
- Is Part Of:
- Neurosurgery. Volume 85:Issue 3(2019)
- Journal:
- Neurosurgery
- Issue:
- Volume 85:Issue 3(2019)
- Issue Display:
- Volume 85, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 85
- Issue:
- 3
- Issue Sort Value:
- 2019-0085-0003-0000
- Page Start:
- E477
- Page End:
- E484
- Publication Date:
- 2019-03-20
- Subjects:
- Pipeline -- Distal Circulation -- Flow Diversion
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyz038 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23456.xml