Harmonization of LC-MS/MS Measurements of Plasma Free Normetanephrine, Metanephrine, and 3-Methoxytyramine. (16th May 2021)
- Record Type:
- Journal Article
- Title:
- Harmonization of LC-MS/MS Measurements of Plasma Free Normetanephrine, Metanephrine, and 3-Methoxytyramine. (16th May 2021)
- Main Title:
- Harmonization of LC-MS/MS Measurements of Plasma Free Normetanephrine, Metanephrine, and 3-Methoxytyramine
- Authors:
- Peitzsch, Mirko
Novos, Talia
Kaden, Denise
Kurlbaum, Max
van Herwaarden, Antonius E
Müller, Daniel
Adaway, Jo
Grouzmann, Eric
McWhinney, Brett
Hoad, Kirsten
Woollard, Gerald
Kema, Ido
Boot, Christopher
Fassnacht, Martin
Sweep, Fred
Loh, Tze P
Horvath, Andrea R
Eisenhofer, Graeme - Abstract:
- Abstract: Background: Plasma-free normetanephrine and metanephrine (metanephrines) are the recommended biomarkers for testing of pheochromocytoma and paraganglioma (PPGL). This study evaluated the status of harmonization of liquid chromatography-tandem mass spectrometry-based measurements of plasma metanephrines and methoxytyramine and clinical interpretation of test results. Methods: 125 plasma samples from patients tested for PPGLs were analyzed in 12 laboratories. Analytical performance was also assessed from results of a proficiency-testing program. Agreement of test results from different laboratories was assessed by Passing-Bablok regression and Bland-Altman analysis. Agreement in clinical test interpretation based on laboratory specific reference intervals was also examined. Results: Comparisons of analytical test results by regression analysis revealed strong correlations for normetanephrine and metanephrine (R ≥ 0.95) with mean slopes of 1.013 (range 0.975–1.078), and 1.019 (range 0.963–1.081), and intercepts of −0.584 (−53.736 to 54.790) and −3.194 (−17.152 to 5.933), respectively. The mean bias between methods was 1.2% (−11.6% to 16.0%) for metanephrine and 0.1% (−18.0% to 9.5%) for normetanephrine. Measurements of 3-methoxytyramine revealed suboptimal agreement between laboratories with biases ranging from −32.2% to 64.0%. Interrater agreement in test interpretation was >94% for metanephrine and >84% for normetanephrine; improvements in interrater agreement wereAbstract: Background: Plasma-free normetanephrine and metanephrine (metanephrines) are the recommended biomarkers for testing of pheochromocytoma and paraganglioma (PPGL). This study evaluated the status of harmonization of liquid chromatography-tandem mass spectrometry-based measurements of plasma metanephrines and methoxytyramine and clinical interpretation of test results. Methods: 125 plasma samples from patients tested for PPGLs were analyzed in 12 laboratories. Analytical performance was also assessed from results of a proficiency-testing program. Agreement of test results from different laboratories was assessed by Passing-Bablok regression and Bland-Altman analysis. Agreement in clinical test interpretation based on laboratory specific reference intervals was also examined. Results: Comparisons of analytical test results by regression analysis revealed strong correlations for normetanephrine and metanephrine (R ≥ 0.95) with mean slopes of 1.013 (range 0.975–1.078), and 1.019 (range 0.963–1.081), and intercepts of −0.584 (−53.736 to 54.790) and −3.194 (−17.152 to 5.933), respectively. The mean bias between methods was 1.2% (−11.6% to 16.0%) for metanephrine and 0.1% (−18.0% to 9.5%) for normetanephrine. Measurements of 3-methoxytyramine revealed suboptimal agreement between laboratories with biases ranging from −32.2% to 64.0%. Interrater agreement in test interpretation was >94% for metanephrine and >84% for normetanephrine; improvements in interrater agreement were observed with use of harmonized reference intervals, including age-specific cut-offs for normetanephrine. Conclusions: Analytical methods for metanephrines are well harmonized between laboratories. However, the 16% disagreement in test interpretation for normetanephrine suggests use of suboptimal method-dependent reference intervals for clinical decision-making for this metabolite. Improved analytical methods and reference interval harmonization are particularly required for 3-methoxytyramine. … (more)
- Is Part Of:
- Clinical chemistry. Volume 67:Number 8(2021)
- Journal:
- Clinical chemistry
- Issue:
- Volume 67:Number 8(2021)
- Issue Display:
- Volume 67, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 67
- Issue:
- 8
- Issue Sort Value:
- 2021-0067-0008-0000
- Page Start:
- 1098
- Page End:
- 1112
- Publication Date:
- 2021-05-16
- Subjects:
- harmonization -- standardization -- metanephrines -- pheochromocytoma -- paraganglioma -- LC-MS/MS
Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1093/clinchem/hvab060 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23485.xml