Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy. Issue 4 (24th January 2020)
- Record Type:
- Journal Article
- Title:
- Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy. Issue 4 (24th January 2020)
- Main Title:
- Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy
- Authors:
- Akinduro, Oluwaseun O
Gopal, Neethu
Hasan, Tasneem F
Nourollah-Zadeh, Emad
Vakharia, Kunal
De Leacy, Reade
Burkhardt, Jan-Karl
Yamamoto, Junichi
Mocco, J
Castilla, Leonardo Rangel
Tze Man Kan, Peter
Boulos, Alan
Levy, Elad
Tawk, Rabih G - Abstract:
- Abstract: BACKGROUND: There is a paucity of literature regarding treatment options for extracranial pseudoaneurysms of the internal carotid artery (ICA). To date, Pipeline Embolization Device (PED; Medtronic Inc) use for the treatment of extracranial pseudoaneurysms of the ICA has only been reported from single-center case series. OBJECTIVE: To evaluate the safety and efficacy of PED for the treatment of extracranial ICA pseudoaneurysms. METHODS: This is a multicenter retrospective study involving 6 high-volume tertiary academic institutions in the United States. We analyzed patients with extracranial ICA pseudoaneurysms treated with PED between January 1, 2011, and January 1, 2019. Clinical assessment was performed pre- and postintervention using the modified Rankin Scale (mRS) and National Institution of Health Stroke Scale (NIHSS) at a minimum of 4-mo follow-up. RESULTS: A total of 28 pseudoaneurysms with a mean diameter of 17.7 mm (range: 4.1-52.5 mm) were treated with PED in 24 patients at 6 participating centers. The mean age was 52.1 yr (17-73) ± 14.3 with 14 females and 10 males. At a mean of 21-mo (range 4-66 mo) follow-up, complete occlusion was achieved in 89% (n = 25/28), with near-complete occlusion (>90% occlusion) in the remainder. There were no periprocedural complications. Postprocedure NIHSS was 0 in 88% (n = 21/24) and 1 in 12% (n = 3/24) of patients, and mRS was 0 in 83% (n = 20/24) and 1 in 17% (n = 4/24) of patients. CONCLUSION: The treatment ofAbstract: BACKGROUND: There is a paucity of literature regarding treatment options for extracranial pseudoaneurysms of the internal carotid artery (ICA). To date, Pipeline Embolization Device (PED; Medtronic Inc) use for the treatment of extracranial pseudoaneurysms of the ICA has only been reported from single-center case series. OBJECTIVE: To evaluate the safety and efficacy of PED for the treatment of extracranial ICA pseudoaneurysms. METHODS: This is a multicenter retrospective study involving 6 high-volume tertiary academic institutions in the United States. We analyzed patients with extracranial ICA pseudoaneurysms treated with PED between January 1, 2011, and January 1, 2019. Clinical assessment was performed pre- and postintervention using the modified Rankin Scale (mRS) and National Institution of Health Stroke Scale (NIHSS) at a minimum of 4-mo follow-up. RESULTS: A total of 28 pseudoaneurysms with a mean diameter of 17.7 mm (range: 4.1-52.5 mm) were treated with PED in 24 patients at 6 participating centers. The mean age was 52.1 yr (17-73) ± 14.3 with 14 females and 10 males. At a mean of 21-mo (range 4-66 mo) follow-up, complete occlusion was achieved in 89% (n = 25/28), with near-complete occlusion (>90% occlusion) in the remainder. There were no periprocedural complications. Postprocedure NIHSS was 0 in 88% (n = 21/24) and 1 in 12% (n = 3/24) of patients, and mRS was 0 in 83% (n = 20/24) and 1 in 17% (n = 4/24) of patients. CONCLUSION: The treatment of extracranial ICA pseudoaneurysms with PED is safe and effective in selected patients. Randomized controlled trials and prospective cohort studies are needed to establish the role of flow diversion for ICA pseudoaneurysms. Graphical Abstract: … (more)
- Is Part Of:
- Neurosurgery. Volume 87:Issue 4(2020)
- Journal:
- Neurosurgery
- Issue:
- Volume 87:Issue 4(2020)
- Issue Display:
- Volume 87, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 87
- Issue:
- 4
- Issue Sort Value:
- 2020-0087-0004-0000
- Page Start:
- 770
- Page End:
- 778
- Publication Date:
- 2020-01-24
- Subjects:
- Pseudoaneurysm -- Internal carotid artery -- Extracranial -- Pipeline embolization
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyz548 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23460.xml