Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial. (27th April 2017)
- Record Type:
- Journal Article
- Title:
- Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial. (27th April 2017)
- Main Title:
- Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial
- Authors:
- Lim, Taeho
Lee, Sanghyun
Oh, Jaehoon
Kang, Hyunggoo
Ahn, Chiwon
Song, Yeongtak
Lee, Juncheol
Shin, Hyungoo - Other Names:
- Zeljezic Davor Academic Editor.
- Abstract:
- Abstract : Purpose . Emergency physicians are at risk for infection during invasive procedures, and the respirators can reduce this risk. This study aimed to determine whether endotracheal intubation using direct laryngoscopes affected protection performances of respirators. Methods . A randomized crossover study of 24 emergency physicians was performed. We performed quantitative fit tests using respirators (cup type, fold type without a valve, and fold type with a valve) before and during intubation. The primary outcome was respirators' fit factors (FF), and secondary outcomes were acceptable protection (percentage of scores above 100 FF [FF%]). Results . 24 pieces of data were analyzed. Compared to fold-type respirator without a valve, FF and FF% values were lower when participants wore a cup-type respirator (200 FF [200-200] versus 200 FF [102.75–200], 100% [78.61–100] versus 74.16% [36.1–98.9]; all P < 0.05 ) or fold-type respirator with a valve (200 FF [200-200] versus 142.5 FF [63.50–200], 100% [76.10–100] versus 62.50% [8.13–100]; all P < 0.05 ). There were no significant differences in intubation time and success rate according to respirator types. Conclusions . Motion during endotracheal intubation using direct laryngoscopes influenced the protective performance of some respirators. Therefore, emergency physicians should identify and wear respirators that provide the best personalized fit for intended tasks.
- Is Part Of:
- BioMed research international. Volume 2017(2017)
- Journal:
- BioMed research international
- Issue:
- Volume 2017(2017)
- Issue Display:
- Volume 2017, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 2017
- Issue:
- 2017
- Issue Sort Value:
- 2017-2017-2017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04-27
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2017/7565706 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23474.xml