Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience. (22nd June 2017)
- Record Type:
- Journal Article
- Title:
- Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience. (22nd June 2017)
- Main Title:
- Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
- Authors:
- Schober, Patrick
Bossers, Sebastiaan M.
Schwarte, Lothar A. - Other Names:
- Obal Detlef Academic Editor.
- Abstract:
- Abstract : In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared spectroscopy (NIRS). Herein, second-generation devices are currently available, for example, the Infrascanner 2000 (Infrascan), that appear suited also for prehospital (H)EMS applications. Since (H)EMS operations are time-critical, we studied the Infrascanner 2000 as a "first-time-right" monitor in healthy volunteers (n = 17, hospital employees, no neurologic history). Further, we studied the implementation of the Infrascanner 2000 in a European HEMS organization (Lifeliner 1, Amsterdam, The Netherlands). The principal results of our study were as follows: The screening for intracranial hematomas in healthy volunteers with first-time-right intention resulted in a marked rate of virtual hematomas (false positive results, i.e., 12/17), rendering more time consuming repeat measurements advisable. The results of the implementation of the Infrascanner in HEMS suggest that NIRS-based intracranial hematoma detection is feasible in the HEMS setting. However, some drawbacks exist and their possible solutions are discussed. Future studies will have to demonstrate how NIRS-based intracranial hematoma detection will improve prehospital decision making in (H)EMS and ultimatelyAbstract : In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared spectroscopy (NIRS). Herein, second-generation devices are currently available, for example, the Infrascanner 2000 (Infrascan), that appear suited also for prehospital (H)EMS applications. Since (H)EMS operations are time-critical, we studied the Infrascanner 2000 as a "first-time-right" monitor in healthy volunteers (n = 17, hospital employees, no neurologic history). Further, we studied the implementation of the Infrascanner 2000 in a European HEMS organization (Lifeliner 1, Amsterdam, The Netherlands). The principal results of our study were as follows: The screening for intracranial hematomas in healthy volunteers with first-time-right intention resulted in a marked rate of virtual hematomas (false positive results, i.e., 12/17), rendering more time consuming repeat measurements advisable. The results of the implementation of the Infrascanner in HEMS suggest that NIRS-based intracranial hematoma detection is feasible in the HEMS setting. However, some drawbacks exist and their possible solutions are discussed. Future studies will have to demonstrate how NIRS-based intracranial hematoma detection will improve prehospital decision making in (H)EMS and ultimately patient outcome. … (more)
- Is Part Of:
- BioMed research international. Volume 2017(2017)
- Journal:
- BioMed research international
- Issue:
- Volume 2017(2017)
- Issue Display:
- Volume 2017, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 2017
- Issue:
- 2017
- Issue Sort Value:
- 2017-2017-2017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-06-22
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2017/1846830 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23449.xml