Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study. (9th October 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study. (9th October 2017)
- Main Title:
- Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study
- Authors:
- Cox, P. B. W.
den Ouden, A. M.
Theunissen, M.
Montenij, L. J.
Kessels, A. G. H.
Lancé, M. D.
Buhre, W. F. F. A.
Marcus, M. A. E. - Other Names:
- Uemura Kazunori Academic Editor.
- Abstract:
- Abstract : Introduction. Evaluation of accuracy, precision, and trending ability of cardiac index (CI) measurements using the Aesculon™ bioimpedance electrical cardiometry (Aesc) compared to the continuous pulmonary artery thermodilution catheter (PAC) technique before, during, and after cardiac surgery. Methods. A prospective observational study with fifty patients with ASA 3-4. At six time points (T), measurements of CI simultaneously by continuous cardiac output pulmonary thermodilution and thoracic bioimpedance and standard hemodynamics were performed. Analysis was performed using Bland-Altman, four-quadrant plot, and polar plot methodology. Results. CI obtained with pulmonary artery thermodilution and thoracic bioimpedance ranged from 1.00 to 6.75 L min −1 and 0.93 to 7.25 L min −1, respectively. Bland-Altman analysis showed a bias between C I B I O and C I P A C of 0.52 liters min −1 m −2, with LOA of [−2.2; 1.1] liters min −1 m −2 . Percentage error between the two techniques was above 30% at every time point. Polar plot methodology and 4-quadrant analysis showed poor trending ability. Skin incision had no effect on the results. Conclusion. CI obtained by continuous PAC and CI obtained by Aesculon bioimpedance are not interchangeable in cardiac surgical patients. No effects of skin incision were found. International clinical trial registration number is ISRCTN26732484 .
- Is Part Of:
- BioMed research international. Volume 2017(2017)
- Journal:
- BioMed research international
- Issue:
- Volume 2017(2017)
- Issue Display:
- Volume 2017, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 2017
- Issue:
- 2017
- Issue Sort Value:
- 2017-2017-2017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10-09
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2017/2635151 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23449.xml