First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality: An Observational Study. (21st March 2017)
- Record Type:
- Journal Article
- Title:
- First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality: An Observational Study. (21st March 2017)
- Main Title:
- First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality: An Observational Study
- Authors:
- Baken, L.
Benoit, B.
Koning, A. H. J.
van der Spek, P. J.
Steegers, E. A. P.
Exalto, N. - Other Names:
- Visentin Silvia Academic Editor.
- Abstract:
- Abstract : Background. With the introduction of three-dimensional (3D) ultrasound it has become possible to measure volumes. The relative increase in embryonic volume (EV) is much larger than that of the crown-rump length (CRL) over the same time period. We examined whether EV is a better parameter to determine growth restriction in fetuses with structural congenital abnormalities. Study Design, Subjects, and Outcome Measures. CRL and EV were measured using a Virtual Reality (VR) system in prospectively collected 3D ultrasound volumes of 56 fetuses diagnosed with structural congenital abnormalities in the first trimester of pregnancy (gestational age 7 +5 to 14 +5 weeks). Measured CRL and EV were converted to z -scores and to percentages of the expected mean using previously published reference curves of euploid fetuses. The one-sample t -test was performed to test significance. Results. The EV was smaller than expected for GA in fetuses with structural congenital abnormalities (−35% p < 0.001, z -score −1.44 p < 0.001 ), whereas CRL was not (−6.43% p = 0.118, z -score −0.43 p = 0.605 ). Conclusions. CRL is a less reliable parameter to determine growth restriction in fetuses with structural congenital abnormalities as compared with EV. By measuring EV, growth restriction in first-trimester fetuses with structural congenital abnormalities becomes more evident and enables an earlier detection of these cases.
- Is Part Of:
- BioMed research international. Volume 2017(2017)
- Journal:
- BioMed research international
- Issue:
- Volume 2017(2017)
- Issue Display:
- Volume 2017, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 2017
- Issue:
- 2017
- Issue Sort Value:
- 2017-2017-2017-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03-21
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2017/1953076 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 23449.xml