Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm. (1st January 2020)
- Record Type:
- Journal Article
- Title:
- Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm. (1st January 2020)
- Main Title:
- Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm
- Authors:
- Solbiati, Luigi
Ierace, Tiziana
Gennaro, Nicolò
Muglia, Riccardo
Cosman, Eric R.
Goldberg, S. Nahum - Abstract:
- Abstract: Purpose: To assess the use of optimized radiofrequency (RF) to achieve larger, spherical ablation volumes with short application duration for hepatocellular carcinoma (HCC). Materials and methods: Twenty-two patients (M: F = 17:5, median age 69.6 year, range 63–88) with 28 HCCs due to HCV + liver cirrhosis underwent RFA. 20/28 (71.4%) were tumors ≤3cm diameter, and 8/28 (28.6%) ranged from 3.2 to 4.2 cm. RF was applied using up to 2500mA via an optimized pulsing algorithm with real-time ultrasound monitoring to detect hyperechogenic changes. Single insertions of an internally cooled electrode were performed using exposed tips of 2 or 3 cm for 13 HCCs and 4 cm for 15 HCCs. All patients were followed-up for a minimum of 5 years with contrast-enhanced computed tomography (CECT). Results: Technical success was achieved without adverse events in all cases. The mean ablation time was 8.5 ± 2.6 min. In 21/28 (75%), ablation duration ranged from 3 to 9 min, with 12 min duration applied in only 7/28 (25%). Mean coagulation diameters were 2.4 ± 0.14, 3.3 ± 0.62, and 4.4 ± 1.0, for 2, 3 and 4 cm electrodes, respectively ( p < 0.01). The sphericity index was 74.9 ± 12.8 for 4 cm electrodes and 81.9 ± 8.0 for shorter electrodes ( p = 0.091). At 5-year follow-up, no tumor ≤3 cm had recurrence and only 2/8 (25%) >3 cm tumors developed local progression. One patient had multifocal disease with no local progression. Conclusion: Efficient delivery of RF energy can considerablyAbstract: Purpose: To assess the use of optimized radiofrequency (RF) to achieve larger, spherical ablation volumes with short application duration for hepatocellular carcinoma (HCC). Materials and methods: Twenty-two patients (M: F = 17:5, median age 69.6 year, range 63–88) with 28 HCCs due to HCV + liver cirrhosis underwent RFA. 20/28 (71.4%) were tumors ≤3cm diameter, and 8/28 (28.6%) ranged from 3.2 to 4.2 cm. RF was applied using up to 2500mA via an optimized pulsing algorithm with real-time ultrasound monitoring to detect hyperechogenic changes. Single insertions of an internally cooled electrode were performed using exposed tips of 2 or 3 cm for 13 HCCs and 4 cm for 15 HCCs. All patients were followed-up for a minimum of 5 years with contrast-enhanced computed tomography (CECT). Results: Technical success was achieved without adverse events in all cases. The mean ablation time was 8.5 ± 2.6 min. In 21/28 (75%), ablation duration ranged from 3 to 9 min, with 12 min duration applied in only 7/28 (25%). Mean coagulation diameters were 2.4 ± 0.14, 3.3 ± 0.62, and 4.4 ± 1.0, for 2, 3 and 4 cm electrodes, respectively ( p < 0.01). The sphericity index was 74.9 ± 12.8 for 4 cm electrodes and 81.9 ± 8.0 for shorter electrodes ( p = 0.091). At 5-year follow-up, no tumor ≤3 cm had recurrence and only 2/8 (25%) >3 cm tumors developed local progression. One patient had multifocal disease with no local progression. Conclusion: Efficient delivery of RF energy can considerably decrease the ablation time in many instances while achieving larger, relatively spherical, and reproducible areas of ablation with extremely low rates of local tumor progression and adverse events. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 37:Number 1(2020)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 37:Number 1(2020)
- Issue Display:
- Volume 37, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2020-0037-0001-0000
- Page Start:
- 861
- Page End:
- 867
- Publication Date:
- 2020-01-01
- Subjects:
- Thermal ablation -- radiofrequency ablation -- hepatocellular carcinoma -- calibration -- interventional oncology
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2020.1790678 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23438.xml