- Temporal and spatial pacemap parameters for identification of cardiac surfaces with critical sites for ventricular tachycardia. (8th July 2022)
- Main Title:
- Temporal and spatial pacemap parameters for identification of cardiac surfaces with critical sites for ventricular tachycardia
- Authors:
- Ueda, Akiko
Katsume, Yumi
Miwa, Yosuke
Mohri, Takato
Tashiro, Mika
Nonoguchi, Noriko
Hoshida, Kyoko
Togashi, Ikuko
Sato, Toshiaki
Soejima, Kyoko - Abstract:
- Abstract: Introduction: Multisurface pacemapping may help identify the surface of interest in scar‐related ventricular tachycardia (VT). This study aimed to investigate the performance of pacemap parameters for detecting critical sites through multisurface mapping. Methods and Results: In 26 patients who underwent scar‐related VT ablation, pacemap parameters including a matching score, the difference between the longest and shortest stimulus‐QRS intervals (Δs‐QRS), and the distance between the good pacemap sites were measured. The parameters were compared between surfaces with and without critical sites and ablation outcomes. A total of 941 pacemap at 56 surfaces targeting 35 VTs were analyzed. A greater Δs‐QRS (40 vs. 8 ms, p < .001) and longer distance between two good pacemap sites (24 vs. 13 mm, p < .001) were observed on the surfaces with critical sites. A similar trend was seen in multisurface pacemapping for the same VTs (52 vs. 18 ms in Δs‐QRS, p = .021; 37 vs. 12 mm in distance, p = .019), although the best pacemap scores were comparable (94 vs. 87, p = .295). The Δs‐QRS > 20 ms and the distance >19 mm showed high positive likelihood ratios (19.8 and 6.1, respectively) for discriminating the surface harboring the critical site. Ablation of VTs fulfilling these parameters was successful on the surfaces, but without the required multisurface ablation. Conclusion: Temporal (Δs‐QRS) and spatial (distance) parameters for good pacemap match sites were excellentAbstract: Introduction: Multisurface pacemapping may help identify the surface of interest in scar‐related ventricular tachycardia (VT). This study aimed to investigate the performance of pacemap parameters for detecting critical sites through multisurface mapping. Methods and Results: In 26 patients who underwent scar‐related VT ablation, pacemap parameters including a matching score, the difference between the longest and shortest stimulus‐QRS intervals (Δs‐QRS), and the distance between the good pacemap sites were measured. The parameters were compared between surfaces with and without critical sites and ablation outcomes. A total of 941 pacemap at 56 surfaces targeting 35 VTs were analyzed. A greater Δs‐QRS (40 vs. 8 ms, p < .001) and longer distance between two good pacemap sites (24 vs. 13 mm, p < .001) were observed on the surfaces with critical sites. A similar trend was seen in multisurface pacemapping for the same VTs (52 vs. 18 ms in Δs‐QRS, p = .021; 37 vs. 12 mm in distance, p = .019), although the best pacemap scores were comparable (94 vs. 87, p = .295). The Δs‐QRS > 20 ms and the distance >19 mm showed high positive likelihood ratios (19.8 and 6.1, respectively) for discriminating the surface harboring the critical site. Ablation of VTs fulfilling these parameters was successful on the surfaces, but without the required multisurface ablation. Conclusion: Temporal (Δs‐QRS) and spatial (distance) parameters for good pacemap match sites were excellent markers for detecting the surface harboring critical sites in scar‐related VT. A multisurface pacemapping can successfully identify the surface of interest. Abstract : Pacemap conducted on the surfaces harboring isthmus demonstrate sites showing good pacemap scores with a long and a short pacing latency (temporal distribtion), in a separate location (spatial distribution), enabling to delineate the putataive isthmus, regardless of whether the entire circuit is on the surface or not. Pacemapping conducted on the surfaces not harboring isthmus demonstrate only modest pacemap scores, surrounded by poorer score. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 33:Number 8(2022)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 33:Number 8(2022)
- Issue Display:
- Volume 33, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 8
- Issue Sort Value:
- 2022-0033-0008-0000
- Page Start:
- 1791
- Page End:
- 1800
- Publication Date:
- 2022-07-08
- Subjects:
- pacemapping -- spatial parameters -- surface of interest -- temporal parameters -- three‐dimensional ventricular tachycardia
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15611 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23426.xml