Simultaneous quantification of dasatinib, nilotinib, bosutinib, and ponatinib using high‐performance liquid chromatography–Photodiode array detection. Issue 8 (12th July 2022)
- Record Type:
- Journal Article
- Title:
- Simultaneous quantification of dasatinib, nilotinib, bosutinib, and ponatinib using high‐performance liquid chromatography–Photodiode array detection. Issue 8 (12th July 2022)
- Main Title:
- Simultaneous quantification of dasatinib, nilotinib, bosutinib, and ponatinib using high‐performance liquid chromatography–Photodiode array detection
- Authors:
- Yokoyama, Yuta
Nozawa, Eiji
Morita, Miho
Ishikawa, Emi
Mori, Takehiko
Sakurai, Masatoshi
Kikuchi, Taku
Matsuki, Eri
Yamazaki, Rie
Kataoka, Keisuke
Jibiki, Aya
Kawazoe, Hitoshi
Suzuki, Sayo
Nakamura, Tomonori - Abstract:
- Abstract: Background: Dasatinib, nilotinib, and bosutinib, second‐generation tyrosine kinase inhibitors (TKIs), and ponatinib, a third‐generation TKI, are approved pharmaceuticals used in the treatment of chronic myeloid leukemia (CML). Although liquid chromatography‐tandem mass spectrometry assays for simultaneous quantification of the four TKIs in human serum have been reported in the literature, a high‐performance liquid chromatography (HPLC) assay that simultaneously quantifies these compounds has not yet been developed. This study aims to establish and validate an efficient HPLC analytical method using a photodiode array (PDA) detector for the simultaneous quantification of the four TKIs. Methods: Calibration standards were prepared by serial dilution of serum samples containing the four TKIs, followed by solid‐phase extraction. The four TKIs were eluted in order within 10 min using a binary HPLC gradient system. Results: The calibration ranges were 2–500 ng/ml for dasatinib, 100–5000 ng/ml for nilotinib, and 10–500 ng/ml for bosutinib and ponatinib. Intra‐day and inter‐day precision and accuracy values were found to be in accordance with the U.S. Food and Drug Administration guidelines. The recovery rates were 92.9%–96.0%, 80.7%–86.1%, 91.6%–99.0%, and 86.4%–92.6% for dasatinib, nilotinib, bosutinib, and ponatinib, respectively. Conclusion: To the best of our knowledge, this is the first report of an HPLC‐PDA analytical method that allows efficient simultaneousAbstract: Background: Dasatinib, nilotinib, and bosutinib, second‐generation tyrosine kinase inhibitors (TKIs), and ponatinib, a third‐generation TKI, are approved pharmaceuticals used in the treatment of chronic myeloid leukemia (CML). Although liquid chromatography‐tandem mass spectrometry assays for simultaneous quantification of the four TKIs in human serum have been reported in the literature, a high‐performance liquid chromatography (HPLC) assay that simultaneously quantifies these compounds has not yet been developed. This study aims to establish and validate an efficient HPLC analytical method using a photodiode array (PDA) detector for the simultaneous quantification of the four TKIs. Methods: Calibration standards were prepared by serial dilution of serum samples containing the four TKIs, followed by solid‐phase extraction. The four TKIs were eluted in order within 10 min using a binary HPLC gradient system. Results: The calibration ranges were 2–500 ng/ml for dasatinib, 100–5000 ng/ml for nilotinib, and 10–500 ng/ml for bosutinib and ponatinib. Intra‐day and inter‐day precision and accuracy values were found to be in accordance with the U.S. Food and Drug Administration guidelines. The recovery rates were 92.9%–96.0%, 80.7%–86.1%, 91.6%–99.0%, and 86.4%–92.6% for dasatinib, nilotinib, bosutinib, and ponatinib, respectively. Conclusion: To the best of our knowledge, this is the first report of an HPLC‐PDA analytical method that allows efficient simultaneous quantification of the four TKIs in the serum of patients with CML. We believe that the method developed herein can improve the efficiency of therapeutic drug monitoring in patients with CML in clinical practice. Abstract : We established the first HPLC‐PDA analytical method for simple and rapid simultaneous quantification in serum concentration of dasatinib, nilotinib, bosutinib, and ponatinib. This HPLC‐PDA method can be applied to the TDM of the four TKIs for CML patients, enabling the construction of an optimal dosing regimen. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 36:Issue 8(2022)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 36:Issue 8(2022)
- Issue Display:
- Volume 36, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 36
- Issue:
- 8
- Issue Sort Value:
- 2022-0036-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-07-12
- Subjects:
- chronic myeloid leukemia -- high‐performance liquid chromatography -- photodiode array detector -- tyrosine kinase inhibitor
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.24598 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23426.xml