Integration of sustained low‐efficiency dialysis into extracorporeal membrane oxygenation circuit in critically ill COVID‐19 patients: A feasibility study. Issue 9 (9th May 2022)
- Record Type:
- Journal Article
- Title:
- Integration of sustained low‐efficiency dialysis into extracorporeal membrane oxygenation circuit in critically ill COVID‐19 patients: A feasibility study. Issue 9 (9th May 2022)
- Main Title:
- Integration of sustained low‐efficiency dialysis into extracorporeal membrane oxygenation circuit in critically ill COVID‐19 patients: A feasibility study
- Authors:
- Arnold, Frederic
Wobser, Rika
Kalbhenn, Johannes
Westermann, Lukas - Abstract:
- Abstract: Background: Severe COVID‐19 can necessitate multiple organ support including veno‐venous extracorporeal membrane oxygenation (vvECMO) and renal replacement therapy. The therapy can be complicated by venous thromboembolism due to COVID‐19‐related hypercoagulability, thus restricting vascular access beyond the vvECMO cannula. Although continuous renal replacement therapy can be performed via a vvECMO circuit, studies addressing sustained low‐efficiency dialysis (SLED) integration into vvECMO circuits are scarce. Here we address the lack of evidence by evaluating feasibility of SLED integration into vvECMO circuits. Methods: Retrospective cohort study on nine critically ill COVID‐19 patients, treated with integrated ECMO‐SLED on a single intensive care unit at a tertiary healthcare facility between December 2020 and November 2021. The SLED circuits were established between the accessory arterial oxygenator outlets of a double‐oxygenator vvECMO setup. Data on filter survival, quality of dialysis, and volume management were collected and compared with an internal control group receiving single SLED. Results: This study demonstrates general feasibility of SLED integration into existing vvECMO circuits. Filter lifespans of ECMO‐SLED compared with single SLED are significantly prolonged (median 18.3 h vs. 10.3 h, p < 0.01). ECMO‐SLED treatment is furthermore able to sufficiently normalize creatinine, blood urea nitrogen, and serum sodium, and allows for adequateAbstract: Background: Severe COVID‐19 can necessitate multiple organ support including veno‐venous extracorporeal membrane oxygenation (vvECMO) and renal replacement therapy. The therapy can be complicated by venous thromboembolism due to COVID‐19‐related hypercoagulability, thus restricting vascular access beyond the vvECMO cannula. Although continuous renal replacement therapy can be performed via a vvECMO circuit, studies addressing sustained low‐efficiency dialysis (SLED) integration into vvECMO circuits are scarce. Here we address the lack of evidence by evaluating feasibility of SLED integration into vvECMO circuits. Methods: Retrospective cohort study on nine critically ill COVID‐19 patients, treated with integrated ECMO‐SLED on a single intensive care unit at a tertiary healthcare facility between December 2020 and November 2021. The SLED circuits were established between the accessory arterial oxygenator outlets of a double‐oxygenator vvECMO setup. Data on filter survival, quality of dialysis, and volume management were collected and compared with an internal control group receiving single SLED. Results: This study demonstrates general feasibility of SLED integration into existing vvECMO circuits. Filter lifespans of ECMO‐SLED compared with single SLED are significantly prolonged (median 18.3 h vs. 10.3 h, p < 0.01). ECMO‐SLED treatment is furthermore able to sufficiently normalize creatinine, blood urea nitrogen, and serum sodium, and allows for adequate ultrafiltration rates. Conclusions: We can show that ECMO‐SLED is practical, safe, results in adequate dialysis quality and enables sufficient electrolyte and volume management. Our data indicate that SLED devices can serve as potential alternative to continuous‐veno‐venous‐hemodialysis for integration in vvECMO circuits. Abstract : Severe COVID‐19 can necessitate multiple organ support including veno‐venous extracorporeal membrane oxygenation (vvECMO) and renal replacement therapy. This feasibility study shows that sustained low‐efficiency dialysis (SLED) devices can be successfully integrated into vvECMO circuits thus providing combined lung and renal replacement therapy in a single extracorporeal circuit. SLED‐ECMO results in volume and electrolyte homeostasis and in an adequate decrease in creatinine and blood urea nitrogen levels without any observation of complications. … (more)
- Is Part Of:
- Artificial organs. Volume 46:Issue 9(2022)
- Journal:
- Artificial organs
- Issue:
- Volume 46:Issue 9(2022)
- Issue Display:
- Volume 46, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2022-0046-0009-0000
- Page Start:
- 1847
- Page End:
- 1855
- Publication Date:
- 2022-05-09
- Subjects:
- COVID‐19 -- ECMO -- ECOS -- MOF -- RRT -- SLED
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.14277 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23433.xml